background image

 

 

Ecosun 

A (mm) 

B (mm) 

300 U+ 

340 

280 

935 280 

600 U+ 
700 U+ 
850 U+ 

Ecosun 

X (mm)  Y (mm) 

Thickness  

600 U+ 

1192 592 

30 

700 U+ 

1192 592 

850 U+ 

1192 800 

300 U+ 

592 592 

A (mm) 

340 
940 
940 
940 

B (mm) 

355 
355 
355 
355 

1. Use 

 

• 

Flats, offices, schools, hospitals, shops, industry and agricultural premises, etc. 

• 

The panels can be installed on flammable materials. 

 

2. Wiring 

 

• 

Power supply: 230V/50Hz 

• 

Protection class I 

• 

IP 44 

• 

The panel is fitted with a thermal fuse. 

 

3. Installing 

 

• 

The panels are intended for vertical installation. In case of horizontal installation on the ceiling of a room, hang the panel 
on a mounting frame, or using chains or cords. 

• 

The minimum distance of the panel front wall and lateral walls from inflammable objects is 10 cm. 

 

Procedure — vertical mounting: 

• 

Mark the holes according to the table, drill out the holes, insert the dowels and drive the screw in to protrude  
approx. 5 mm. 

• 

Always fix the panel on two upper locks, two lower locks serve to a reverse suspension of the panel. 

• 

Connect the lead-in cable to a fixed power distribution in accordance with the colour marking of wires. 

• 

Put the panel on the two upper locks. 

 

Procedure – horizontal mounting 

• 

Position the mounting frame in the location where the panel is to be placed, using a pen, mark holes according to the 
holes on the frame.  

• 

Drill the holes, insert the wall anchors and attach the mounting frame with the screws. 

• 

Connect the lead-in cable to the mains in accordance with the colour of the conductors. 

• 

Slide the panel into the mounting frame. 

Fixing Frame 