background image

Feniex Industries, Inc.
1.800.615.8350
 /

 

feniex.com

5

Green/White

Mode 0 Rear

Blue/White

Black

Red

Orange

Green

Blue

Red/Black

White

Orange/Black

Green/Black

Blue/Black

White/Black

Black/White

Mode 0 Front

Mode 1

Mode 2

Mode 3

Cruise Mode

Takedown

Left Alley

Right Alley

Flashing TD/Alley

Flood Mode

Dim

Arrow Left

Arrow Right

W/B +        B/W

Red/White

Center Out

Pattern Changer

WIRING DIAGRAMS

12V+

Activates rear-facing 

modules, corners & sides

12V+

12V-

12V+

12V+

12V+

12V+

12V+

12V+

12V+

12V+

12V+

12V+

12V+

Activates front-facing 

modules & corners
Warning Mode 1. 

Overrides Mode 0

Warning Mode 2. 

Overrides Mode 0 & 1

Warning Mode 3.

Overrides Mode 0, 1 & 2

Corner Modules.

10% Brightness

Overrides Modules 1, 2 & 3 

Flash Patterns
Steady Burn.

Overrides Flashing

Steady Burn.

Overrides Flashing

Flashes Takedown & Alley 

Lights

Activates Flood Mode.

Dims Lightbar. Takedown, 

Alley & Flood Unaffected
Left Arrow.

Overrides Flashing

Right Arrow.

Overrides Flashing

12V+

12V+

Center-Out Arrow.

Overrides Flashing

Momentary, cycles through 

DIM MODE

Activate the flash mode by applying the 
flashmode wire to a 12V(+). Activate Dim 

Mode by extending the blue/black wire to a 
12v (+). Tap the pattern changer, red/white 
wire to cycle through the dim modes.

Dim Mode is only available on hard-wire 

models. This mode will dim all modes 
except for Takedown functions & Flood 
Mode. 

ATTENTION:

Содержание FUSIONGPL FN-4420

Страница 1: ...l Accordingly any copyrighted material of Feniex and its licensors contained herein or in the Feniex products described in this Price List may not be copied reproduced distributed merged or modified t...

Страница 2: ...ate the previously listed products of Feniex Industries Inc Please read this manual thoroughly before installing or operating your new product in order to prevent any damage or injury Failure to follo...

Страница 3: ...UIPMENT DIMENSIONS 44 5 12 13 1 75 3 65 SPECIFICATIONS Voltage 10 18 Volts DC Current Draw Warranty 5 years 15 Amps 20A Fuse 125 ofCircuitLoad Input Power External Fuse 12 VDC Class 1 J595 CT13 J1113...

Страница 4: ...ut Slow In Out Fast Combo All Slow 15 16 Combo All Fast Combo Fast Slow FLASH PATTERNS CRUISE PATTERNS Activate Cruise Mode by extending the green wire to a 12v latching switch 1 Apply 12v to the gree...

Страница 5: ...arning Mode 2 Overrides Mode 0 1 Warning Mode 3 Overrides Mode 0 1 2 Corner Modules 10 Brightness Overrides Modules 1 2 3 Flash Patterns Steady Burn Overrides Flashing Steady Burn Overrides Flashing F...

Страница 6: ...load to the end of the red wire Do not use a circuit breaker or fusible link 2 Connect the opposite end of the fuse to the 12v terminal of the battery Do not use more than 1 foot of wire between the...

Страница 7: ...DOWN Activate the factory configured takedown function by extending the white wire to a 12v latching switch ALLEY LIGHTS Activate the factory configured alley lights by extending the red black white w...

Страница 8: ...lay Use the 4200 Software to program the desired function of the Fusion 44 Lightbar When the RJ45 Data Link wire is connected to the 4200 Relay this will override any other wire input to the Fusion 44...

Страница 9: ...hicle until the bar is snugly mounted Use the included lock nut as a jam nut for extra security Ensure the vehicle s door will close without any interference 5 Drill and secure the bracket to the vehi...

Отзывы: