INSTRUCTIONS
1. To activate the unit, extend a wire from the 12V+ to a 12V+ terminal
post. Extend a wire from 12V- to the ground post of the vehicle’s
battery.
2. Select a Mode by applying a 12V+ signal to one of the three
programmable Mode terminals. The default pattern will become
active.
Note: Mode3 overrides Mode2, and Mode2 overrides Mode1.
3. To program the selected Mode with a different flash pattern, scroll
through the patterns by momentarily connecting the ‘Pattern Changer
/ Sync’ terminal to 12V-. The current pattern will turn off and when
12V- is removed the next pattern will activate.
4. To synchronize more than one Flasher unit, activate the same flash
pattern on all units and connect the ‘Pattern Changer / Sync’ terminals
together.
5. All 4 outputs are rated at 5 amps each. When the red LED is
illuminated, outputs are set to 12V+ activation.
WIRING DIAGRAM
Output 4
Output 3
Output 2
Output 1
Mode 1
Mode 2
Mode 3
12V -
12V +
Pattern
Changer/
Sync
Switch
Positive
20A Fuse
Positive
Ground
12V
Halogen or LED
Light