 INSTRUCTIONS

1. To activate the unit, extend a wire from the 12V+ to a 12V+ terminal 

post. Extend a wire from 12V- to the ground post of the vehicle’s 

battery.

2. Select a Mode by applying a 12V+ signal to one of the three 

programmable Mode terminals. The default pattern will become 

active. 

Note: Mode3 overrides Mode2, and Mode2 overrides Mode1.

3. To program the selected Mode with a different flash pattern, scroll 

through the patterns by momentarily connecting the ‘Pattern Changer 

/ Sync’ terminal to 12V-. The current pattern will turn off and when 

12V- is removed the next pattern will activate.

4. To synchronize more than one Flasher unit, activate the same flash 

pattern on all units and connect the ‘Pattern Changer / Sync’ terminals 

together.

5. All 4 outputs are rated at 5 amps each. When the red LED is 

illuminated, outputs are set to 12V+ activation.

WIRING DIAGRAM

Output 4

Output 3

Output 2

Output 1

Mode 1
Mode  2
Mode 3

12V -

12V +

Pattern 

Changer/

Sync

Switch

Positive 

20A Fuse

Positive

Ground

12V

Halogen or LED 

Light

Содержание FLASHER H-2220

Страница 1: ...hted material Accordingly any copyrighted material of Feniex and its licensors contained herein or in the Feniex products described in this Price List may not be copied reproduced distributed merged or modified transmitted transcribed stored in retrieval system or translated into any language or computer language in any form or by any means without prior written permission of Feniex Industries Inc...

Страница 2: ...g provides all the information necessary to safely operate the previously listed products of Feniex Industries Inc Please read this manual thoroughly before installing or operating your new product in order to prevent any damage or injury Failure to follow the listed instructions in this manual may result in damage to your products or personal injury Proper installation of this product requires go...

Страница 3: ...stries Inc 1 800 615 8350 feniex com 3 EQUIPMENT DIMENSIONS Feniex University Before installing the 4x Flasher watch our instructional video series Feniex University Use the link below feniexuniversity com 4 2 6 1 ...

Страница 4: ...ifferent flash pattern scroll through the patterns by momentarily connecting the Pattern Changer Sync terminal to 12V The current pattern will turn off and when 12V is removed the next pattern will activate 4 To synchronize more than one Flasher unit activate the same flash pattern on all units and connect the Pattern Changer Sync terminals together 5 All 4 outputs are rated at 5 amps each When th...

Страница 5: ...Out Slow In Out Fast Combo Slow Combo Fast Left Arrow Slow Left Arrow Fast 16 17 18 19 Right Arrow Slow Right Arrow Fast Center Out Slow Center Out Fast 20 Brake Pop Steady on FLASH PATTERNS Warranty 2 years 22 patterns 10 18V DC Voltage Flash Pattern 4 3 Programmable Modes Outputs 5 Amps per output Amps Short circuit protection SPECIFICATIONS 21 Left Side 1 2 Steady On 22 RightSide3 4SteadyOn ...

Отзывы: