Please maintain HiMESO™ properly and keep it in the best working condition

· After each use, please clean the cover and the slots inside of the device thoroughly with 

   a clean cloth or towel, and wipe them dry.

· Please wipe the charging base with a soft cloth or towel.

· After finishing the Nano Meso Mode and Phototherapy Mode, please remove the cartridge 

   with serum and clean the Cartridge with serum installation slot.

· Please do not use cleaning products containing alcohol, gasoline, or acetone to clean the 

   device. These substances may irritate the skin.

· Please do not place HiMESO™ in an acidic or alkaline liquid.

· Please do not put HiMESO™ in a dishwasher, microwave oven or high-pressure container, 

   otherwise it may cause an accident or cause injury.

· Please do not wash the HiMESO™ device with water.

· The device must not be immersed in water.

· Please avoid exposure to high temperatures, moisture, heavy pressure and impact.

· Please keep the product out of reach of children to prevent accidents.

· Please do not use it near electrical appliances such as TVs and radios.

· Please do not use while the product is charging.

· Please charge HiMESO™ when it is in a low battery state to extend the battery life.

· Please use the original charging dock and charging cable of HiMESO™.

· Please do not disassemble, modify or repair the device by yourself.

· Please use the product only for the specific purposes described in this manual.

Maintenance

Frequently Asked Questions

The most frequently asked questions about HiMESO™ are listed below.If you cannot find 

proper answers, please call the customer service hotline for more information.
The indicator light of HiMESO™ does pulse in the breathing rhythm after the charger is 

connected

  The battery is completely depleted and it can take a few minutes to recognize the charger.
  The HiMESO™ device is not properly placed in the charging base.

HiMESO™ does not respond after pressing the function mode button

Cannot switch to other modes

·

  The device is turned off.Please press and hold the power button for 1.5 seconds to turn on 

  the device.

  The battery is depleted.Please charge the device.

  The microprocessor has a temporary malfunction.Please connect the charging cable to 

  restore its function.

  Please ensure that the buttons and fingers are clean and try again.

·

·

  The HiMESO™ charging cable connector or power charger are not connected properly.

·

·
·

·

  If the device cannot switch during use, there may be residual essence in the device. Please 

  put it in a ventilated place to dry for one to two days before trying again.

·

Содержание HiMESO

Страница 1: ...Instruction Manual...

Страница 2: ...standard the con tact area is larger make it easy to take care of every inch of skin Three button switch mode and simple operation enable you to get started quickly The body is small and portable so t...

Страница 3: ...view Side view Top cover Bottom Interface Cover Cartridge with serum installation slot Infrared sensing area Button NanoMeso Mode Phototherapy Mode Wireless charging port Phototherapy lamp red light i...

Страница 4: ...harging port Placement slot Charging cable connector of the dock W i r e l e s s C h a r g i n g S t a t i o n F H W C S 1 0 I P X 4 I n p u t 5 V 1 0 0 0 m A O n l y u s e w i t h f e m o o i H i M E...

Страница 5: ...Wireless charging dock mirror Mirror Wireless charging dock connector...

Страница 6: ...Cartridge with serum Other accessories Capsule cap Nanocrystalline needle surface Serum chamber Charging cable Quick Start Guide...

Страница 7: ...e with serum vertical ly down into the installation slot until you hear a slight click to ensure it is placed correctly Place the cover back on and it s done 1 Align the backside of the wireless charg...

Страница 8: ...he Nano Meso Mode please remove the Cartridge with serum and clean the cover and the installation slot of the Cartridge with serum After using the Nano Meso Mode and Phototherapy Mode some people may...

Страница 9: ...HiMESO Phototherapy Mode The machine will emit a short beep and the corresponding indicator light will turn on The Phototherapy Mode has two settings to choose from the low energy red light and the h...

Страница 10: ...e treatment has nished Follow the Installation of cartridge with serum instructions to install the cartridge with serum Press the Nano Meso Mode button to turn on the Nano Meso Mode If you need to adj...

Страница 11: ...lift the wrist so that the needle surface cannot evenly touch the skin Please be very careful when using the essence in the area around the eyes Do not let the essence be in direct contact with the e...

Страница 12: ...he face for more than 3 minutes After the treatment the desired skincare products can be applied as usual Note Warning If the skin feels dry during the treatment the skin can be hydrated accordingly I...

Страница 13: ...nsert the plug into the power outlet Align the charging port on the bottom of the Himeso device with the charging port on the wireless charging dock and insert it into the place ment slot with the bac...

Страница 14: ...e to extend the battery life Please use the original charging dock and charging cable of HiMESO Please do not disassemble modify or repair the device by yourself Please use the product only for the sp...

Страница 15: ...Time 4 hours Battery Standby Time 280 days Interface three buttons six indicator lights Product Speci cations HiMESO does not vibrate after pressing the Nano Meso Mode button The battery is depleted...

Страница 16: ...changes or changes In case of dispute the company reserves the right of nal decision on the interpretation Within the scope of the law the company reserves the right of nal interpretation Note Produc...

Отзывы: