Measure

Signal range

Measured value

Option3

Option installed

  44

92

Panel

cut-out

96

48

16

8

75

Information Menu

To enter the 

“Information Menu”

 press the SQ button. The 

“Information Menu”

 allows to visualize information and does 

not allow to modify the configuration of the instrument. It is 

not affected by the “PASSWord” function. During operation 

with the 

“Information Menu”,

 alarms remain “frozen” and are 

kept on-hold. Leaving the 

“Information Menu”

 returns to the 

measuring state of the instrument, without restart.

Information Menu Tree -

 See page 5.

Rollback - 

After 30 seconds without interaction from the 

operator, the instrument leaves the 

“Information Menu”

.

Button SQ -

 Selects the visible option.

Button UP -

 Moves vertically along the available menu op-

tions.

Button LE -

 Leaves selected menu or leaves the 

“Informa

-

tion Menu”

.

Information Menu - Operation

Mechanical Dimensions (mm)

Configuration

See menu for Alarm1

See menu for Alarm1

See menu for Alarm1

Alarm1

Maximum

Minimum

Memory of minimum

Option1

Option installed

Option2

Option installed

Signal Range

Input Low

Display Low

Input High

Display High

Memory of maximum

“On / Off”

“Max” / “Min”

Setpoint

Hysteresis

Delay

Setpoint2

Counts

Seconds

Second 

setpoint

Configuration (Conf) -

 Information on  the configured input 

signal range (600V, 5A, ...), and the values for input low “ILo”, 

display low “dLo”, input high “IhI” and display high “dhI”.

Maximum (MAX) - 

Value of the maximum display.

Minimum (MIn) - 

Value of the minimum display.

AlarmX (ALX) - 

Configuration of  alarm X. The sequence of 

information shows if the alarm is being managed (“On/Off”), 

the alarm type (“Max/Min”), the setpoint, the hysteresis value, 

the activation delay and the value of setpoint2 (“Off” or the 

setpoint2 value).

OptionX (OptX) - 

Type of module installed. If there is no 

module shows “nonE”.

Measure (MEAS)- 

Multimeter function. Shows the value of 

the input signal without scaling. This is the real value the 

instrument is receiving on signal terminals.

Information Menu - Description

Содержание M40-D

Страница 1: ...d 1Adc Housing 96x48mm DIN standard Display in 4 or 5 digits Maximum and minimum display memory scalable reading filters steps signal autocorrection measure function peak hold alarms with double setpoints 5 levels of brightness Universal AC and DC power modules and up to 3 modules for signal retransmission and control Panel Meters FEMA ELECTRÓNICA USER S Manual 2149r01 Panel meter 96x48mm ...

Страница 2: ...the installation Using the instrument in ways not specified by the manufacturer may lead to a reduction on the specified protection level Disconnect the instrument from power before starting any maintenance and or installation action Risk of electrical shock Instrument terminals can be connected to dangerous voltage Instrument protected with double isolation No earth connection required The instru...

Страница 3: ...ion 61010 1 add to the power line a protection fuse acting as disconnection element easily accessible to the operator and identified as a protection device Power H fuse 250mA time lag Power L fuse 400mA time lag Front View Rear View Power Connections Input signal connections DC Current Range Close Jumpers 5 Adc 1 Adc Table 1 DC currents Input signal range selection The current measuring has a sing...

Страница 4: ...ction Functions available Fixed digits yes configurable Filter on display yes recursive configurable Steps yes configurable Memory of maximum yes Memory of minimum yes Zeros to the left yes configurable Add zero to the right yes configurable Password yes configurable Measure function yes Auto correction high yes Auto correction low yes Peak Hold yes Double setpoints yes Brightness control yes 5 le...

Страница 5: ...nical Dimensions mm Configuration See menu for Alarm1 See menu for Alarm1 See menu for Alarm1 Alarm1 Maximum Minimum Memory of minimum Option1 Option installed Option2 Option installed Signal Range Input Low Display Low Input High Display High Memory of maximum On Off Max Min Setpoint Hysteresis Delay Setpoint2 Counts Seconds Second setpoint Configuration Conf Information on the configured input s...

Страница 6: ...r 30 seconds without interaction from the operator the instrument leaves the Configuration Menu discarding all changes Button SQ Moves horizontally on the menu Allows selec tion of the current option displayed During a value selection menu for example a setpoint value validates the value on display Button UP Moves vertically on the menu Displays the available menu options During a value selection ...

Страница 7: ...s Minimum brightness Brightness Maximum brightness Default brightness Display See menu for Alarm1 See menu for Alarm1 See menu for Alarm1 Left Zeros With left zeros Without left zeros Maximum Minimum Memory of maxim Reset of maxim Memory of minim Reset of minim Peak Hold Time Sec Steps Counts for step Average Fixed Digits Fix digits Setpoint2 Second setpoint Add Right Zero Add zero XXXX0 Not add X...

Страница 8: ... setpoint The second setpoint allows for the creation of acti vation windows If the alarm is configured as maximum with setpoint 1000 and setpoint2 is configured at 1500 the alarm will be activated between 1000 and 1500 and the alarm will be deactivated when display is 1000 and 1500 Setpoint2 is affected on the same way as the setpoint with hysteresis and delays Display Menu Functions on this menu...

Страница 9: ...Off Time 1 a 3999 seconds before disabling the hold Time 4000 infinite hold The counting of seconds is started each time there is an in crease in the display value Alarms will follow the input signal while hold is active When the instrument detects that the displayed value does not correspond to the expected value the display will flash and alternate with a message h udr Hardware underrange The in...

Страница 10: ...ria B Barberà del Vallès September 2011 Daniel Juncà Quality Manager All instruments are warranted against all manufacturing defects for a period of 24 MONTHS from the shipment date This warranty does not apply in case of misuse accident or manipulation by non authorized personnel In case of mal function get in contact with your local provider to arrange for repair Within the warranty period and a...

Страница 11: ...User s Manual M40 D FEMA ELECTRÓNICA Page 11 T H I S P A G E B L A N K ...

Страница 12: ...ducts ELECTRONIC INSTRUMENTATION FOR INDUSTRY www fema es FEMA ELECTRÓNICA S A Altimira 14 Pol Ind Santiga E08210 Barberà del Vallès BARCELONA SPAIN Tel 34 93 729 6004 www fema es Fax 34 93 729 6003 info fema es Panel Meters Standard 96x48mm Panel Meters Miniature 48x24mm Panel Meters Small 72x36mm ...

Отзывы: