SERIES I4 · Model I4P

Section INDUSTRIAL . ISOLATED SIGNAL CONVERTERS

www.fema.es 

15

13.3 

Output range

At the ‘

Output range

’ (

out

) menu entry, select the output signal range to 

4/20 mA (value ‘

420

’) or to 0/10 Vdc (value ‘

010

’).

The output signal range selected can be later customized to operate in a 

reduced range of signal (see section 13.6).

Output range

13. Configuration menu (cont.)

Resistances

1 KOhm range

100 KOhm range

1 MOhm range

10 KOhm range

Ntc sensors 2

Potentiometer

Passive 

potentiometer

Kohms

value

Ntc R

25 

Ntc ß

Potentiometer signal

Ntc 44030

Ntc 44031

Ntc 44032

Ntc 44034

Ntc 44033

Input  signal  ranges  are  also  accessible  as  predefined  ‘

configuration 

codes

’ 

(see section 8)

. The predefined ‘

configuration codes

’ include some 

additional input - output ranges that are not available at the ‘

Input range

’ 

(

InP

) list of ranges.

  example:  select  the  ‘

0/1500 ºC

’  input  range  for  thermocouple  J 

‘0/1500 ºC=4/20 mA’  or  ‘0/1500 ºC=0/10 Vdc’  configuration.  To 

customize to a smaller range (for example 0/1250 ºC) see section 13.6. 

To manually select the output signal see section 13.3. To customize 

the output range for a smaller range (for example 0/1500 ºC=8/12 mA 

or 0/1500 ºC=1/5 Vdc) see section 13.6.

Passive potentiometer signal

Содержание I4 Series

Страница 1: ...www fema es SERIES I4 Model I4P USER S MANUAL ISOLATED SIGNAL CONVERTER Section INDUSTRIAL 5488r02 Process mA Vdc NTC Temperature tc Temperature Pt Temperature Potentiometer Resistances INDUSTRIAL...

Страница 2: ...t quality and available customization 1 How to order 1 How to order 2 2 Material included 2 3 Additional information 2 4 Installation and start up 3 5 Typical applications 3 6 SOS mode 3 7 Messages 3...

Страница 3: ...an easy resolution of the problem Additionally each instrument can be assigned a custom label code of up to 8 characters see Table 1 that can be displayed at the front display or at the messages sequ...

Страница 4: ...gnals see section 13 6 Notes Code uSEr indicates that a user custom configuration is active and it does not match any of the listed codes This code is non selectable for information only Example selec...

Страница 5: ...ctive output mA in mA out 7 8 9 mA mA 4 20mA passive output external loop power needed mA out mA in 7 8 9 mA mA 0 10Vdc common Vdc 7 8 9 common Vdc fuse Pt Ntc resistance thermocouple Pt 3rd wire ther...

Страница 6: ...tion HOW TO OPERATE INSIDE THE CONFIGURATION MENU Inside the configuration menu use the front keypad to move through menu entries parameters and select configuration values Key SQ functions as the ENT...

Страница 7: ...force menu press the LE 3 key or press the key UP 5 key until the parameter appears and select by pressing the SQ key or wait without pressing any key until the automatic rollback activates 10 4 How t...

Страница 8: ...ASURING POTENTIOMETERS The instrument can be configured to measure potentiometer signals 3 wires from potentiometers with nominal value between 250Ohms and 15KOhms See connections at Table 10 The inst...

Страница 9: ...of NTC can read signals down to 0Ohms and up to 16MOhms PREDEFINED CONFIGURATION CODES See Table 16 for a list of predefined input output configuration codes To activate a code see section 13 1 CUSTO...

Страница 10: ...Total error Thermoc R 059 159 50 1768 C 58 3214 F 0 15 FS 2 C 060 160 0 1600 C 32 2912 F 0 15 FS 2 C 061 161 0 1000 C 32 1832 F 0 15 FS 2 C Table 24 Temperature ranges for thermocouple S Input signal...

Страница 11: ...ctivate an alpha value of 0 0390 see section 13 4 This parameter is associated to the sensor and depends on the sensor manufacturer CURRENT THROUGH THE SENSOR The instrument generates 960uA through Pt...

Страница 12: ...FEMA MANUFACTURING FOR INDUSTRIAL AUTOMATION 12 T h i s p a g e b l a n k...

Страница 13: ...4 20mA passive max 30Vdc on terminals voltage output 0 10Vdc max 11Vdc min 0 05Vdc typ minimum load 10KOhm CONFIGURATION SYSTEM key pad display accessible at the front of the instrument configuration...

Страница 14: ...or 4 20mA or 010 for 0 10Vdc signal input At the Thermocouples tc parameter select from the available thermocouples J K N E T R S C or B At the Pt sensors Pt parameter select from the available pt sen...

Страница 15: ...Ntc R25 Ntc Potentiometer signal Ntc 44030 Ntc 44031 Ntc 44032 Ntc 44034 Ntc 44033 Input signal ranges are also accessible as predefined configuration codes see section 8 The predefined configuration...

Страница 16: ...nfiguration Temperature units Degrees celsius Degrees fahrenheit Offset Offset in degrees Cold junction Pt alpha Process configuration Field correction low ok flashes while field correction is being a...

Страница 17: ...s expressed in x xxmA or x xxVdc These four parameters define the relation between the input and the output signal see Table 31 and can be modified independently to match the specific input output rel...

Страница 18: ...ed at the process parameters see section 13 6 for example Proc 150 0 select Percentage Prct to read the percentage of signal where 0 is the value assigned to the input signal low parameter and 100 is...

Страница 19: ...gnal to maximum value in case of input signal overrange and to underrange output signal to minimum value in case of input signal underrange 13 10 Tools menu Key LE messagesfunction Input signal value...

Страница 20: ...th of the filter slows the response speed of the instrument Value 0 disables the filter at the Dead band d bnd parameter set a value between 0 0 and 100 0 This is a percentage of the input signal high...

Страница 21: ...SERIES I4 Model I4P Section INDUSTRIAL ISOLATED SIGNAL CONVERTERS www fema es 21 T h i s p a g e b l a n k...

Страница 22: ...on 10 For a full vision of the configuration menu structure see section 13 Function code Enter the function code see section 8 Output range Resistances 1KOhm range 100KOhm range 1MOhm range 10KOhm ran...

Страница 23: ...put signal low Output signal high Process low Process high Process decimal point 0 0 to 100 0 SOS mode of output Display information Input signal value Output signal value Label Process value Key LE m...

Страница 24: ...errange to 21mA 10 4Vdc to underrange to 3mA or 0 05Vdc or to hold value See the On error on Er parameter at section 13 10 Function code codE 10 c 010 Input range InP 4 20mA Output range out 4 20mA Te...

Страница 25: ...ctrovalves together with signal and or control cables The use of shielded cables is recommended to prevent the coupling of environmental electromagnetic noise connected to earth only one cable end sid...

Страница 26: ...FEMA MANUFACTURING FOR INDUSTRIAL AUTOMATION 26 Notes...

Страница 27: ...SERIES I4 Model I4P Section INDUSTRIAL ISOLATED SIGNAL CONVERTERS www fema es 27 Notes...

Страница 28: ......

Отзывы: