SERIES · 

BAR

Section SPECIAL . BAR METERS

 

EBR 

· QUICK INSTALLATION GUIDE

F

E

MA

 · MANUFACTURING FOR INDUSTRIAL AUTOMATION 

www.fema.es 

5499r00

The instrument is provided with the following elements :

• 1 x instrument 

EBR

• 1x plug-in screw terminals, connected to the instrument (for input signal and power)
• 2x metal side fixations for panel mount
• 1 x quick installation guide

2. Material included

3. Additional documentation

User’s manual EBR

www.fema.es/docs/5495_EBR_manual_en.pdf

Datasheet EBR

www.fema.es/docs/5497_EBR_datasheet_en.pdf

Quick installation guide EBR

www.fema.es/docs/5499_EBR_installation_en.pdf

CE Declaration of conformity

www.fema.es/docs/5250_CE-Declaration_MBR_en.pdf

Warranty

www.fema.es/docs/4153_Warranty1_en.pdf

Web

www.fema.es/Series_BAR

Scan the QR code to directly 

access the user’s manual of 

this instrument.

Security

EN-61010-1

Electromagnetic C.

EN-61326-1

50

1969-2019

YEARS

Q

Certified Quality

ISO 9001

5

Extended Warranty

YEARS

Process

±20 mA

Process

±10 Vdc

Process

0/10 Vdc

Process

4/20 mA

4. How to order

Table 1 

INPUT SIGNAL CONNECTIONS

INPUT  

signal

Input terminals

1

2

3

4/20 mA

mA+

mA -

0/10 Vdc

comm.

+ Vdc

±20 mA

± mA

comm.

±10 Vdc

comm.

± Vdc

Table 2 

POWER CONNECTIONS

POWER  

Power terminals

4

5

24 Vdc ±10% 

(isolated)

+ 24 Vdc

0 Vdc

1. Installation and start-up

1. Read how to operate the instrument (see section 9)
2. Install the instrument at the panel

• consider to move the panel installation to the last step if your panel prevents access to 

the rear configuration keys.

3. Connect the power supply to power-up the instrument (see section 5)

• for a list of display errors see section 11

4. Connect the input signal to the instrument (see section 5)
5. Configure the input signal (see section 10)

• default configuration is 4/20 mA=0/100 %
• if you need as different reading, operate span and offset configurations to adjust the read-

ing to your needs.

6. Modify the offset (see section 9) if needed
7. Modify the span (see section 9) if needed

Access the user’s manual (see section 3) for detailed explanations. Do not 

forget to read the ‘

installation precautions

’ section at the user’s manual.

When the marks ‘

Attention

’ or ‘

Risk of electrical shock

’ appear, read 

the documentation for information about the nature of the risk.

6. Dimensions and panel cut-out ‘mm’ (in)

1.

 Remove the two metal side fixations at the sides of the instrument.

2.

 Insert the instrument, through the panel front, into the panel cut out.

3.

 Place again the two metal side fixations, and screw them against the panel.

7. How to panel the instrument

Power 24 Vdc isolated, consumption <2 W

Power fuse 200 mA time-lag

fuse

5. Connections

Vdc signal
common
mA signal

power +24 Vdc

power 0 Vdc

1 2 3

-

+

4 5

 O+ 

Offset

 O-

 S+ 

S- 

Span

 

Input

 I+  I-

Table 3 

FRONT VIEW

100%

75%

50%

25%

0%

Bar graph

Percentage

Table 4 

HORIZONTAL AND VERTICAL MOUNTINGS

100%

75%

50%

25%

0%

100%

75%

50%

25%

0%

Panel 

cut-out

21.5 mm

(0.85 in.)

92.5 mm

(3.64 in.)

24 mm

(0.95 in.)

96 mm

(3.78 in.)

100%

75%

50%

25%

0%

8. Front view

Reference

Description

EBR

Indicador de barra

EBR.1442

Indicador de barra con personalización

(0.31 in.)

(0.60 in.)

15

8

55 mm

(2.16 in.)