Quick installation guide C60-FL

www.fema.es

Series C

14. 

Factory configuration

13. 

Configuration menu

Press ‘

SQ

’ 

(

<

for 1 second to access  

the ‘Configuration menu’.

FEMA ELECTRÓNICA, S.A.

 | Manufacturing for Industrial Automation | www.fema.es . [email protected]

50

1969-2019

YEARS

5

Extended Warranty

YEARS

Electromagnetic C.

EN-61326-1

Security

EN-61010-1

Q

Certified Quality

ISO 9001

Instrument configuration

   Main instrument 

‘rAtE’ (instant flow meter)

   Sensor 

NPN

   ‘K’ Decimal point 

XX.xxxx

   ‘K’ Factor 

01.0000

Instant flow configuration

   Time Base (Multiplier) 

x1 (x seconds)

   Divider 

/1

   Resolution 

XXXXX.x

Total flow configuration

   Multiplier 

x1

   Divider 

/1

   Resolution 

XXXXX.x

   Preset 

0

   Mode 

‘uP’

Alarm 1

   Instrument link 

‘rAtE’ (instant flow)

   Type 

‘MAx’ alarm as maximum

   Setpoint 

100.0

   Hysteresis 

0 counts

   On alarm

      Active time 

0.0 (seconds)

      Alarm flash 

off

      Reset to 0 

off

      Reset to preset 

off

Alarm 2

   Instrument link 

‘tot’ (total flow)

   Type 

‘MAx’ alarm as maximum

   Setpoint 

100.0

   Hysteresis 

0 counts

   On alarm

      Active time 

0.0 (seconds)

      Alarm flash 

off

      Reset to 0 

off

      Reset to preset 

off

Fast access

   Alarm1 

off

   Alarm2 

off

   Preset 

off

Key Left

   Reset 

off

   Display background instr. 

on

Advanced Sensor

   Antirrebound filter 

0

   Gate 

0.5 seconds

   Reading delay 

off

   Trigger level 

15

   Average filter 

0

Option1 configuration

   Analog output

      Instrument link 

‘rAtE’ (instant flow)

      Display low 

0

      Display high 

100.0

   Modbus RTU

      Address 

1

      Speed 

‘9.6’ (9600 kbps)

      Bits  

8n1

Tools

   Option.1 

relay

 (retains last configuration value)

   ‘Eco’ mode 

off

   Reset on display 

off

   Counter overrange 

Flash

   ‘Cut-off’ reading 

0

   Brightness 

3

   Password 

off

Main 

instrument

Instant flow 

(ratemeter)

Total flow 

(totalizer)

Instrument 

conf.

Pick-up

‘PNP’ signal

Sensor

‘NPN’ signal

‘K’ factor

1 to 999999

‘K’ decimal point

x.x.x.x.x.x.

Instant flow 

conf.

Time Base 

(Multiplier)

Divider

Resolution

1 to 999999

1 to 999999

x.x.x.x.x.x.

Total flow 

conf.

Multiplier

Divider

Resolution

1 to 999999

1 to 999999

x.x.x.x.x.x.

Preset

Counting 

mode

1 to 999999

Other sensors

Setpoint

Hysteresis

Alarm type

Alarm 1

Instrument 

link

Active time

On alarm

Flash

Reset to 0

Reset to Preset

Setpoint

Hysteresis

Alarm type

Alarm 2

Instrument 

link

On alarm

Flash

Active time

Reset to 0

Reset to Preset

Key ‘UP’ 

(fast access)

Preset ‘total’

Setpoint 1

Setpoint 2

Key ‘LE’

See background 

instrument

Reset ‘total’

Gate

Advanced 

Sensor

Antirrebound 

filter

Trigger level

Average 

filter

0 to 100

Option 1  

configuration

(value selected 

at /Tool/Out.1)

Analog 

output

Display Low

Display High

Instrument 

link

Modbus RTU Address 1 to 247

Speed Kbps

Format

Minimum

Brightness

Maximum

Standard

Counter 

overrange

Option 1

analog output

relay

Tools

Modbus RTU

the ‘420’ parameter gives access to 

the calibration menu for the analog 

output. See the user’s manual. Only 

necessary  in  case  of  new  installa-

tion of an analog output module.

‘Eco’ mode

5 to 255 seconds

Reset on display

Password

Factory reset

Version

‘cut-off’ 

reading

Reading delay