background image

FEMA ELECTRÓNICA - Page 4

User’s Manual - Instrument MAG983-TF

Default Parameters

«41 1E»

Default Parameters

«42 3E»

Default Parameters

«43 1E»

Default Parameters

«44 1E»

Default Parameters

«45 1E»

Default Parameters

«46 1E»

Default Parameters

«61 4E»

Instrument without fixed zeroes

«62 1E»

«Time Multiplicator» x1

«63 1E»

Time Base between 0.5 and 1 seconds

«64 4E»

«Decimal Multiplicator» x1

«46 1E»

without Decimal Point

«51 2E»

Default Parameters

«52 3E»

Default Parameters

«53»

Default Parameters

«54 3E»

Default Parameters

«55»

Default Parameters

«56 1E»

Default Parameters

«66 1E»

Default Parameters

«1» 500

Default Parameters

«2» 1000

Default Parameters

«3» 1.0000 «Scale Factor»

6.- Introducing how to programm the instrument______________________________

The MAG983 instruments do not have programming keypad accesible to the end user. To modify the configuration
of the instrument, access the internal pins and configure the contacts indicated on «figure 1». These contacts
will allow the activation of the required programming codes.

Example  .- To activate code «46 2E» (activation of decimal point at position XXXXX.X) close and release one

after the other, contacts «4», «6», «2» and «E»

Contact 4

Number «4» appears on display

4

Contact 6

Number «6» appears on display

46 21

Together with code «46» appears the number «1» indicating that code «46»
has a value of «1», this means configuration without decimal point

Contact 2

Number «2» substitutes number «1»

46 2

Contact E

The instrument activates the decimal point

XXXX . XX

Note .- the programming codes «1», «2» and «3», are composed of 1 digit only. When closing contact «3» the
display will show a 5 digits number, which is the actual value of the «Scale Factor» (by default its value is
«1.0000»). To modify each one of these 5 digits, close contacts «1» to «5» and once the desired value is on the
display close «E» to validate.

7.- Reset of the Configuration and Default Parameters___________________________

«41 -1E» Reset of the instruments configuration. Activates the default parameters

In order to place this code, close «4», «1», «1», «±» and «E»

±

Select «±» to swtich between active instruments. MAG983 units have 2 internal instruments,
a ratemeter and a counter. By default after the activation of a «41 -1» code, the ratemeter remains
activated. Close «±» to activate the counter

Common

Figure1 .-
Connecting the programming contacts

C/-

Contact E 

(ENTER)

Contact 1

Contact 2

Contact 3

Contact 4

Contact 5

Contact 6

Содержание MAG983-TF

Страница 1: ...USER S MANUAL HT1598 r140705 Instrument MAG983 TF IDEAL SOLUTIONS for applications where a display proportional to the input frequency is desired The operator can not change the programming value of t...

Страница 2: ..._____________ DISPLAYS Led 7 segments red color SEGMENTS 9 9 9 9 9 9 DIGITHEIGHT 14 2 mm 0 56 READING from 0 to 999999 DECIMALPOINT 6 positions factory selected or see section 9 INPUTSIGNAL PNP NPN Na...

Страница 3: ...J K Closed Antirrebound Filters at 100 Hz Open Antirrebound Filters at 10KHz Note Use filter 100Hz for input type mechanical contact in order to filter contact rebounds G H J K 4 Internal Jumpers Trig...

Страница 4: ...release one after the other contacts 4 6 2 and E Contact 4 Number 4 appears on display 4 Contact 6 Number 6 appears on display 46 21 Together with code 46 appears the number 1 indicating that code 46...

Страница 5: ...maximum frequency 3250 Hz 61 1E DigitfixedtozeroXXXXX0 these codes move the display to the left 61 2E DigitfixedtozeroXXXX00 by adding zeroes to the right 61 3E DigitfixedtozeroXXX000 61 4E No fixed z...

Страница 6: ...y connected to a power supply of the correct voltage and frequency Do not use other power supply otherwise permanent damage may be caused to the unit Do not connect the unit to power sources heavily l...

Страница 7: ...FEMA ELECTR NICA Page 7 User s Manual Instrument MAG983 TF 13 Notes for instrument MAG 983 TF...

Страница 8: ...CELONA ESPA A SPAIN Tel 34 93 729 6004 www fema es Fax 34 93 729 6003 info fema es more products ELECTRONIC INSTRUMENTATION FOR INDUSTRY www fema es Large Displays for TIME Miniature Panel Meters Stan...

Отзывы: