FEMA ELECTRÓNICA - Page 3
User’s Manual - Series MAG983-CR
The correct operation of the unit needs the following jumpers to be
selected .-
Jumpers at rearside
A,D,F closed
Jumpers internal
H,G closed
Jumpers internal J,K
open
(filters
disabled
)
Jumper L closed
Enables frontal RESET button
Connections for «RESET» .-
mechanical contact
between terminals 7 and 3
Connections for «CONTROL» .- mechanical contact
between terminals 6 and
4
open contact INHIBITS the counting
closed contact ALLOWS the counting
4.- Jumpers and Connections_______________________________________________
7 6 5 4 3 2 1
FEDCBA
+
-
Jumper L
G
H
J
K
RESET
7 6 5 4 3
CONTROL
7 6 5 4 3
INSTALLATION PRECAUTIONS
.- The in-
stallation and use of this instrument must be
done by qualified operators. The unit has not
power switch, and
the unit has not internal protection
fuse
, and will start operation as soon as power is connected.
The installation must incorporate an external main switch with
a protection fuse of :
fuse 50 mA (at 230 Vac power)
SAFETY CONSIDERATIONS
.- Before starting any
operation of adjustment, replacement, maintenance or
repair, the unit must be disconnected from the power
supply.The unit is designed to be mounted in a metal panel. To
prevent electrical or fire hazard, do not expose the unit to
excessive moisture. Do not operate the unit in the presence of
flammable gases or fumes, such as environment constitutes a
definite safety hazard.
5.- Security Prescriptions__________________________________________________
POWER SUPPLY
.- The characteristics of the power supply are
written on the attached label. Please make sure that the unit is
correctly connected to a power supply of the correct voltage and
frequency. Do not use other power supply otherwise permanent
damage may be caused to the unit. Do not connect the unit to power
sources heavily loaded or to circuits which power loads in cycle
ON-OFF or circuits with power inductive loads.
IN CASE OF FIRE
1.- Disconnect the unit from the power supply.
2.- Give the alarm according to the local rules.
3.- Switch off all the air conditioning devices.
4.- Attack the fire with carbonic snow, do not use
water in any case.
WARNING : In closed areas do not use sys-
tems with vaporized liquids.
POWER
~
~
+
-
2 1
6.- Declaration of Conformity_______________________________________________
Manufacturer.-
FEMA ELECTRÓNICA, S.A.
Address .- Pol. Ind. Santiga - Altimira 14 (T14 - N2)
E-08210 Barberà - BARCELONA
ESPAÑA - SPAIN
Conforming products
Model .-
MAG983-CRH, MAG-983-CRM, MAG983-CRS,
MAG983-CR7
We hereby declare that the above products conform to the
essential protection requirements of Directives and
Harmonised Standards stated below
.
Signed .-
D. Juncà
Position.-
Quality Manager
Place .-
Barberà, 2005
DIRECTIVES
EUROPEAN DIRECTIVE FOR LOW VOLTAGE D73/23/CEE AMENDED BY D93/
68/CEE
. Equipments powered from 50 to 1000 Vac. and / or from 75 to 1500 Vdc.
ELECTROTECHNICAL REGULATION FOR LOW VOLTAGE (RBT) ITC21,
ITC29, ITC35.
Equipments with power supply lower than 50 Vac and/or 75 Vdc.
EUROPEAN DIRECTIVE FOR ELECTROMAGNETIC COMPATIBILITY D89/
336/CEE AMENDED BY D93/68/CEE
STANDARDS
IMMUNITY
UNE EN 50082-1 (1998)
EMISSIONS
UNE EN 50081-1 (1994)
ELECTRICAL SAFETY
UNE EN 61010-1 (1996)
UNE EN 60204-1 (1997)
DECLARATION OF CONFORMITY