FEMA ELECTRÓNICA . Series M . M40-A
4
Digits
number of digits
4
led
7 segments led
color
red or green
digit height
14 mm
Reading
maximum reading*
9999
minimum reading*
-9999
*with ‘Dummy’ zero ’99990’
/
‘-99990’
decimal point
configurable X.X.X.X.
overrange
flash reading (see section 1.11)
underrange
flash reading (see section 1.11)
acquisitions
15 readings / second
display refresh
15 readings / second
step response*
<300mSec (input 0 to 95% FS)
<500mSec (input 0 to 50% FS)
<1100mSec (input 0 to 10% FS)
*The response time for a TrueRMS measuring system is faster for higher am
-
plitude signals. Response times are given for input steps of 10
%, 50
% and
95
% of the full scale (FS), calculated at 99
% of end reading.
Measure
measured signals
AC voltages and AC currents
measure technique
True RMS
crest factor
3 for nominal accuracy
5 for accuracy of 2.5 % FS
accepted connections
phase-neutral and phase-phase
measure coupling
‘AC’ or ‘AC+DC’(see section 1.9)
scales
accuracy
thermal drift
signal continuity
+20 % FS
minimum signal accepted 0.5 % of the scale
reading will be ‘0’ for lower signals
input impedance
bandwidth (at 99 % FS)
1.3 KHz for AC voltages
2.0 KHz for AC currents
minimum frequency
25 Hz for reading oscillation ±1 count
1.7 Technical specifications
Power
power ‘H’
85 a 265 Vac/dc
power ‘L’
11 a 60 Vdc y 24/48 Vac
isolation*
2500 Veff with power ‘H’
1500 Veff with power ‘L’
*all units tested during 60 seconds
consumption
<1.5 W only meter
<4.0 W meter with options
Configuration
3 buttons front keypad
(and rear jumper)
Front protection
IP54 standard
IP65 optional (see section 3.2))
Output and control options
relays, analog outputs, serial communi-
Mechanical
mounting
panel
connections
plug-in screw terminal
housing material
ABS, polycarbonate (V0)
weight
<150 grams
front size
96 x 48 mm (1/8 DIN)
panel cut-out
92 x 44 mm
depth from panel
91 mm (including terminals)
Temperature
operation
from 0 to +50 ºC
storage
from -20 to +70 ºC
warm-up time
15 minutes
Scale
Accuracy
Zin
(at 50 Hz and 60 Hz)
Max. signal overload
Offset drift
Span drift*
*includes offset drift
600
Vac
0.25
% FS
14 M
1000
Vac permanent
150
ppm/ºC
200
ppm/ºC
100
Vac
0.15
% FS
2 M
200
Vac permanent
75
ppm/ºC
100
ppm/ºC
10
Vac
0.15
% FS
200 K
200
Vac permanent
75
ppm/ºC
100
ppm/ºC
1
Vac
0.15
% FS
20 K
65
Vac permanent
75
ppm/ºC
100
ppm/ºC
100
m
Vac
0.20
% FS
1 K
4.5
Vac permanent
75
ppm/ºC
150
ppm/ºC
5
A
ac
0.20
% FS
20 mOhm
16
Aac @5 seconds
75
ppm/ºC
150
ppm/ºC
1
A
ac
0.20
% FS
20 mOhm
16
Aac @5 seconds
75
ppm/ºC
150
ppm/ºC
Table 3 - Technical specifications for each input scale