4

FELTON

WATER PATH

Input 

 

 

2 × M10 × 1

Output 

 

  1/2

˝ BSP

Flow 

  

 

max. 22 l/min at 300kPa

Pressure range  

 

Min 150kPa - Max 500kPa

Difference of pressure 

Max. 100kPa/14.5psi

Maximum outlet temperature  45°C

Hot inlet temp range 

55°C - 80°C

Cold inlet temp range 

5°C - 25°C

ELECTRONICS

Power supply  

 

100V-240V AC/50-60Hz

Power consumption  

Standby 

<

 0.5 W, max. 18W

PLEASE READ THE MANUAL CAREFULLY BEFORE STARTING THE INSTALLATION. AFTER COMMISSIONING AND TESTING THE 

SYSTEMS FUNCTIONALITY, THIS DOCUMENT MUST BE GIVEN TO THE END USER OF THE SYSTEM.

PRODUCT TO BE DISCONNECTED BEFORE LINE TEST

In case of a power cut, the unit will remain inactive until the power is back on. 

GENERAL

This installation manual contains instructions for the correct installation of the 

Tate Digital Controller

. The warranty will be invalidated 

if the product is not installed according to these instructions.

Installation must be carried out by qualified installers in accordance to this installation manual. AS/NZS3500 standards, rules and safety

 

regulations do apply.

PLACE OF INSTALLATION

The 

Tate Digital Controller

 must be installed in an accessible place and in accordance to this installation manual. This ensures a 

problem-free service and maintenance procedure.

NOTICE

TOOLS REQUIRED

7. Drill

4. Torx screwdriver 
(included in box 1)

3. Phillips screwdriver

2. Drill bit ø 5mm

1. Pencil

5. ø 30-32mm hole saw

8. Spirit level

6. Utility knife

DANGER OF ELECTRIC SHOCK!

ELECTRICAL INSTALLATION

Before opening the housing, the mains connection must be switched off.  Work on electrical parts and connections must be

 

carried out by qualified electrician. Country-specific standards and regulations do apply.

PRECAUTIONS

1. 

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of 
experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible 
for their safety.

2. 

Children should be supervised to ensure that they do not play with the appliance.

3. 

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a 

hazard.

4. 

This appliance contains battery that are only replaceable by skilled persons.

5. 

An electronic copy of the installation and user guides are available on the Felton website – please visit www.felton.co.nz

MAINTENANCE

Felton products are made of high quality materials and require only minimal maintenance. The following maintenance tips help to preserve 
the surface and prevent damage through incorrect cleaning. Fittings and control parts should be wiped dry after used. Only use mild cleaning 

products that contain soap. The following must not be used: Scourers, abrasive sponges, hydrochloric acid, lime, plaster or cement removers, 
solutions or cleaning agents containing acid (pH 

 4), lime scale remover or vinegar-based cleaner – and cleaning agents where the chemical 

solution is not known which may be sold as special cleaner for fittings.

Содержание TATE SMARTFLOW

Страница 1: ...1 TATE SMARTFLOW DIGITAL SHOWER MIXER INSTALLATION GUIDE INSTALLATION GUIDE TATE Smartflow Digital Shower Mixer...

Страница 2: ...2 FELTON...

Страница 3: ...R INSTALLATION GUIDE Control Unit Installation 7 Measurements 5 Tools Required 4 Notice 4 Scope of Application 6 Digital Mixer Installation 11 Operational Test 17 CONTENTS Connecting the Flow Controll...

Страница 4: ...HOCK ELECTRICAL INSTALLATION Before opening the housing the mains connection must be switched off Work on electrical parts and connections must be carried out by qualified electrician Country specific...

Страница 5: ...rol Mounting Tube 4 Cable Tie 5 Control Sleeve 8 Foam Seal 6 Control Wheel 7 Control Housing 2 Screw MEASUREMENTS 155mm 55mm 115mm 1 Temperature Control Unit 4 Set of Screws 2x 5x50mm 2 12V AC Adapter...

Страница 6: ...ended B Wall Mounted TATE SMARTFLOW DIGITAL SHOWER MIXER Cable length 6m max Handset outlet Cold in Hot in Note The wheel can be tted anywhere in the showering area Note The Digital Mixer must not be...

Страница 7: ...e is installed in conduit for ease of maintenance The Control Tube can be reduced in length if required by cutting along the cutting slot see Fig 2 Prepare a 30 32mm hole in the finished wall deck or...

Страница 8: ...astic sleeve leave this on until later in the installation Control Mounting Tube Data Cable Push the Control Mounting Tube into the hole until the front flange sits against the wall Apply a silicone b...

Страница 9: ...is aligned with the Plastic Mounting Tube This tightens the lugs on the inside of the wall Tighten until there is no rotation of the Control Housing 6 7 Pull the red strip to release the connector fr...

Страница 10: ...10 FELTON 8 Thread in the cable and fit the Control Wheel onto the Housing Fit the Control Sleeve onto the Control Wheel Ensure that you fit the Control Sleeve in the correct orientation SIDE VIEW...

Страница 11: ...SHOWER MIXER INSTALLATION GUIDE 10 Inside the Temperature Control Unit 9 Remove the cover DIGITAL MIXER INSTALLATION Outlet Hot Cold Inlets Fixing holes Fixing hole Cover retaining holes Transformer 1...

Страница 12: ...tal Mixer 99mm 1 Mark fixing holes 56mm 2 Drill fixing holes 99mm 56mm 5mm 3 Install the Digital Mixer If installed vertically use orientation shown 99mm 1 Mark fixing holes 56mm If installed vertical...

Страница 13: ...s and filters to the water supply feed Large retaining bolt A Connect the brass adaptors into the flexi hoses B Fit both flexi hoses with the brass adaptor on firmly into the unit box C Fit the large...

Страница 14: ...o the Digital Mixer and fit the short retaining bolt with torx screw driver supplied ADVICE Push in firmly 14 Connect the Data Cable coming from the Control Unit Use the large 6 pin connector and push...

Страница 15: ...WER MIXER INSTALLATION GUIDE 15 Connect the power cable coming from the transformer Use the connector and push firmly into the socket Feed the cable through the guide slot in the front of the Digital...

Страница 16: ...ssioning Please see User Guide IMPORTANT Electrical supply must be installed by a qualified electrician if required Power cable connection IMPORTANT Fit cables into slots to allow cover to properly cl...

Страница 17: ...the unit and plumbing for leaks Once the plumbing is confirmed to be water tight connect the power supply and conduct the operational test below OPERATIONAL TEST Digital Mixer with Flow Control Unit i...

Страница 18: ...tic Test in User Guide Difference in supply pressure between hot and cold water is greater than 100kPa Balance pressure to eliminate difference Constant flow of water Unit will not turn off Carry out...

Страница 19: ...does not cover any damage to product due to abuse negligence or improper installation This warranty is given on the understanding that the product is installed by a registered plumber and operated ac...