![Fellowes Proteus A3/125 Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/fellowes/proteus-a3-125/proteus-a3-125_technical-and-service-manual_550532021.webp)
Proteus A3/125 Technical Service Manual
Revised 09 .15 .11
19
Replace Fuse
1
Open the fuse holder with the screwdriver blade
2
Insert a new fuse
3
Replace the holder into the laminator
Remove/Replace Cord Socket
1
Disconnect 2 power wires from the Power Switch .
2
Disconnect 2 power wires from the Cord Socket .
3
Disconnect the grounding wire from Noise Filter (center
connector) .
4
Remove the screw from the grounding wire .
5
Press down on 4 locking tabs on the Cord Socket and
push the Socket out .
DO THIS FIRST
Unplug the Laminator
TOOLS
Flathead screwdriver
DO THIS FIRST
Remove Housing Cover
TOOLS
Long nose pliers
Phillips screwdriver