Reset the table to factory settings (re-initialization) 

•  To reset the table to factory settings, re-initialize the control unit using the keypad. 

 

— Be sure there are no obstacles under the table that would prevent it from reaching  

its lowest position.

 

— Press and hold  the UP 

s

 and DOWN 

buttons simultaneously for more than 3 

seconds. The legs will begin to move down at half speed of normal operation.

 

— Continue to hold the UP 

s

 and DOWN 

buttons. 

 

— The legs will move down to the lowest position, then rebound 

1

/

16

" to 

3

/

16

" (2mm to 

5mm) and stop.

 

— Release the UP 

s

 and DOWN 

buttons at the same time. This completes the  

re-initialization procedure.

Adjust gyro anti-collision sensitivity

•  The default anti-collision sensitivity is G-1. To increase or decrease the sensitivity of the 

table to obstacles in the path of its movement:

 

— Press and hold the 

S

 button for more than 5 seconds. The display shows “–––”.

 

— Release 

S

 and, within 3 seconds, press the 

3

 button. The display shows “G–X”, where  

X is a number from 0 to 4. 

 

— Press the UP 

s

 or DOWN 

s

 button to increase or decrease the gyro sensitivity  

level. There are five levels of sensitivity: “G–0”, “G–1”, “G–2”, “G–3” and “G–4”.  

“G–4” indicates the highest sensitivity and and “G–0” is no gyro sensitivity. 

 

— Press and hold the 

S

 button for more than 3 seconds. This completes the adjustment.

Error codes

VictoryLX 2-leg 

Operation

If one or more motors are changed in a system, the table 

must be reset to factory settings.

If the legs do not move when general operation is 

attempted, the gyro sensitivity adjustment may be  

too high.

Error Code

Description

Troubleshooting

E01

Leg malfunction

1.  Check that the leg cables are securely plugged into the leg and control unit.

2. Inner parts of leg are broken. Replace the leg.

E03

Table top overload

1.  Remove some weight from the table.

E04

Control unit malfunction

1.  Re-initialize the system.

E05

Keypad button stuck

1.  Toggle the button to restore normal function.

2. Replace the keypad if the button remains stuck.

E06

Communication interruption

1.  Check the cable connection between the keypad and control unit. Verify that the cable is 

securely plugged into the control unit.

2. If the problem is not resolved, replace the keypad or control unit.

E12

Gyro error

1.  Communication is abnormal; power 

ON

 to normalize communication.

2. Table is tilted; straighten table or wait one minute before operating table.

IMPORTANT: The table should be re-initialized after every 1,000 cycles; every six months; or if power is cut or cable is unplugged accidentally. 

When re-initializing, be sure there are no obstacles under the table that would prevent it from reaching its lowest position

Содержание esi Victory LX 2-leg

Страница 1: ...Assembly instructions Victory LX 2 leg Model 2VT LX C36 24 ___ Model 2VT LX C36 30 ___ Model 2VT LX C48 24 ___ Model 2VT LX C48 30 ___ ___ SLV BLK or WHT Electric height adjustable table base...

Страница 2: ...ewdriver Phillips 1 and 2 bits Caution When drilling holes for the wood screws guard against drilling through the top of the worksurface Always check that screws used to attach components to the works...

Страница 3: ...0 deep position the rear cross channel 6 5 from the rear edge of the table With 30 0 tables position the rear cross channel 9 5 from the rear edge of the table These positions of the frame will align...

Страница 4: ...ach leg under the frame support as shown Install the cam lock With the lever arm upward insert the long end of the cam lock first as shown After the cam lock is installed rotate its lever arm toward t...

Страница 5: ...ypad can reach the control unit and the motor cables can extend from the control unit to both motors Attach the control unit using the two M5x15 2 Phillips round head screws Step 7 make cable and cord...

Страница 6: ...Press the UP s and DOWN t buttons individually to test operation End your test with the legs lowered Unplug the power cord If there are problems with operation check that all cable and cord connectio...

Страница 7: ...ts to ensure free unobstructed movement If necessary adjust the leveling glides on the feet to level the worksurface Plug the power cord into an AC outlet Re initialize the system See Step 8 on page 6...

Страница 8: ...he worksurface to a memory stop position Press and hold the desired memory button 1 2 or 3 The worksurface will move to the saved position and then stop Lower stop position To set the lower stop posit...

Страница 9: ...thicknesses Move the table to the lowest position by pressing the DOWN button Measure and record the height of the top of the worksurface Press and hold S until the first LED number blinks Press and...

Страница 10: ...ensitivity Press and hold the S button for more than 3 seconds This completes the adjustment Error codes VictoryLX 2 leg Operation If one or more motors are changed in a system the table must be reset...

Страница 11: ......

Страница 12: ...anty or any implied warranty and the purchaser s sole remedy is limited to the repair or replacement at ESI s option of the product or any defective part Costs such as installation labor fees or expre...

Отзывы: