background image

OWNER’S MANUAL

WINDOW AIR CONDITIONER

MODELS

13-04522/13-04531/13-04532 /13-04546/13-04547

00246-20/08/07

Before using this air conditioner, please read the following instructions carefully and keep
this manual along with your proof of purchase in a safe place for future reference.

© Tous droits réservés, Sunrise Tradex Corp., 2007

Содержание 13-04522

Страница 1: ...13 04532 13 04546 13 04547 00246 20 08 07 Before using this air conditioner please read the following instructions carefully and keep this manual along with your proof of purchase in a safe place for...

Страница 2: ...T OPERATION ELECTRONIC CONTROL MODELS LED display control panel 8 Cooling 9 Fan only 9 Energy Saver mode 10 Sleep mode 10 Setting the timer 10 Filter cleaning warning light 10 Remote Control 11 13 MEC...

Страница 3: ...p the plug 7 Do not start or stop the unit by plugging in or pulling out the power cord 8 Always check the power cord for signs of damage before use If the power cord is damaged contact SUNRISE TRADEX...

Страница 4: ...ow and that all accessories and hardware parts provided with your air conditioner as shown are included Top mounting rail Foam gasket Right expandable panel Tools needed Level Gloves Flat blade and Ph...

Страница 5: ...either load conductor exceeds a predetermined value The cord will remain out of power until the device is manually reset This device protects against electric shock and reduces fire risks in the power...

Страница 6: ...than the top of the storm window frame Make sure that the drain holes of the storm window frame are not blocked by caulking or painting PREPARING THE AIR CONDITIONER FIX THE EXPANDABLE PANELS ON THE A...

Страница 7: ...t and right expandable panels into the vertical window sashes 3 On each side place the frame locking bracket between the frame extension and the window sill Using a 3 4 screw secure the panel screwing...

Страница 8: ...NERGY SAVER modes Increase decrease the hours when setting the timer for an automatic start or shut off of the air conditioner LED display shows the temperature or time settings when timer is on When...

Страница 9: ...vel based on the set temperature The fan speed will increase or decrease in order to adjust the cooling airflow as per the set temperature If the room temperature does not get too warm the fan speed w...

Страница 10: ...the SLEEP mode and the unit will continue to operate as originally programmed 1 Set to COOL mode and adjust the temperature on the air conditioner 2 Press on the SLEEP button 3 This mode can be cance...

Страница 11: ...s from the remote controller to the unit If you keep the remote in a position that hinders a good signal transmission it could result in a 15 minutes time lag 11 REMOTE CONTROL ON OFF Turns the unit o...

Страница 12: ...10 minutes Set the CLOCK time before activating the timer If you adjust the clock time after setting the timer it will accordingly impact on the time you have set on the timer Static electricity batt...

Страница 13: ...play the setting time right beside is flashing 2 Press or to set the numbers of hours 1 24 before the unit TURNS OFF 3 Wait for 3 seconds and the set time will stop flashing the timer OFF is now activ...

Страница 14: ...lockwise towards MIN COOL 1 When the set temperature is reached the thermostat will start and stop the compressor in ordre to maintain set temperature AIR VENT AND EXHAUST CONTROL 1 For maximum contin...

Страница 15: ...E HOUSING 1 Turn the unit off and unplug the unit 2 Wipe the surface of the unit with a soft damp cloth Never immerse the unit 3 Air dry completely and reconnect the unit Never use chemical products o...

Страница 16: ...ack wait 3 minutes before starting the unit Change time settings Clear out the air inlets and outlets curtains blinds etc Close or move the heat source Clean the air filter Change set temperature Incr...

Страница 17: ...SERVICE Contact SUNRISE TRADEX Customer Service for Replacement parts Technical support Warranty claims Customer service 5000 BTU 100 150 ft2 9 14 m2 6000 BTU 150 250 ft2 14 23 m2 7000 BTU 250 300 ft...

Страница 18: ...nit enclosure or to other outer features caused by wear 4 Filter 5 Damage caused by repairs or modifications to the air conditioner made by any person not duly authorized by SUNRISE TRADEX CORP 6 Insu...