Malfunction
Possible Cause
Corrective Action
Vacuum cleaner cannot be
switched on.
Circuit breaker of
power supply has
tripped.
Ensure power supply.
Vacuum cleaner in
remote control
operation.
Set operating-mode selector to “
I
”.
Reduced vacuuming capacity. Vacuum cleaner not
fitted correctly.
Mount lid properly and shut both
fasteners completely.
Vacuum system
clogged.
Clean vacuum hose and extension
tubes.
Fleece filter bag full.
Replace fleece filter bag.
Flat-fold filter full.
Replace flat-fold filter.
Disposal bag full.
Replace disposal bag.
Dust escapes during vacuum-
ing.
Incorrect mounting
position of flat-fold
filter.
Correct mounting position of flat-
fold filter.
No suction capacity when wet
vacuuming.
Container full.
Empty container.
The automatic shut-off (while
wet vacuuming) does not
respond.
Sensors contaminated/
dirty.
Clean sensors and their
intermediate space using a brush.
Container full.
For electrically non-conductive
liquids, check filling level and empty
container, as required.
Automatic filter cleaning (AC)
inoperative.
Vacuum hose not
connected.
Connect vacuum hose.
The automatic filter cleaning
(AC) cannot be switched
on/off.
Contact the FEIN Customer
Service.