![Fein JCM125Q Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/fein/jcm125q/jcm125q_instruction-manual_4116158012.webp)
12
en
Assembly instructions.
Before mounting or replacing cutting tools or accessories, pull the power plug.
This preventive safety measure rules out the danger of injuries through acci-
dental starting of the power tool.
Mounting the cooling lubricant pump
(Figure 2).
Prevent the flow of liquid
along the cord into the socket
or into the core drill, as this can lead to elec-
tric shock. Tie a bow in the cord near the
plug, so that any liquid can drip off.
Only use cooling lubricant that is capable of
being pumped like Slugger Cutting Fluid.
➤
Insert the filled cooling lubricant pump
into the holder on the drill stand housing
intended for this purpose.
➤
Connect the cooling lubricant hose.
Mounting the chip guard (Figure 3).
The chip guard must be mounted at all
times.
➤
Mount the chip guard.
➤
For removal of collected chips, remove
the chip guard.
➤
Before starting the cutting procedure,
lock the chip guard with the hook.
WARNING
WARNING
Fig. 2
Cooling lubricant connection
Fig. 3
Chip guard
Hook for
locking
3 41 01 165 21 0.book Seite 12 Mittwoch, 7. September 2011 12:05 12