Dustex 35LX; Dustex 35LX AC; Dustex 35MX; Dustex 35MX AC
Troubleshooting
C-SC_CSSM
Version 1.0
2017-01-19
All rights reserved by FEIN, especially in case of property rights applications.
FEIN retains all rights of disposal, such as copying and circulation
.
Page
5
of
6
Fault
Remedy
Automatic filter cleaning does not work
•
Connect the suction hose
Filter cover is not closed properly
•
Close the filter cover properly (must audibly engage)
•
Check the suction system for leaks and eliminate any leaks
•
Check the installation position of the flat-fold filter and correct if necessary
•
Check for leaks between the suction head and dirt container and eliminate any
leaks
•
Check the "On/Off" switch of the automatic filter cleaning system and replace if
necessary
Magnet does not attract.
•
Measure the resistance (5.0 – 5.5 k
Ω)
•
Replace the magnet if necessary
Automatic filter cleaning will not switch off
•
Check the control board and replace if necessary
•
Check the "On/Off" switch of the automatic filter cleaning system and replace if
necessary
Suction device does not switch on in tool mode
•
Check the control board and replace if necessary
•
Power tool does not have the prescribed performance data (min. 100 Watt,
max. 2200 Watt). Check the power tool
Содержание Dustex 35 LX AC