Fein Dustex 25L 9 20 27 Скачать руководство пользователя страница 21

29

en

After finishing the wet vacuuming, 
clean the sensors and the space in 
between using a brush.
Switch the vacuum cleaner off imme-
diately as soon as foam or water 
comes out, and empty the container.
In case of short-circuiting and/or 
heavy escaping of dust, switch the vac-
uum cleaner off immediately and dis-
connect it from the power supply.
For transport of the vacuum cleaner, 
activate the vacuum cleaner's lockable 
castor brake.

Repair and customer service.

Check the connections, seals and 
hoses. Have damage repaired only 

through a qualified repair person and 
only using original FEIN replacement 
parts.
Use commercially available, non-
scouring cleaning agents and water for 
cleaning the vacuum cleaner. After 
cleaning, allow the vacuum cleaner to 
dry completely.

Empty the container each time 
after using and remove coarse 
debris and dust.

Empty the container after vacuuming 
liquids. Afterwards, run the vacuum 
cleaner with the accessories con-
nected for several minutes in order to 
dry them. 
Dispose of used flat-fold filters and fil-
ter bags according to statutory regula-
tions.
When replacing the power cable is 
required, have this carried out by 
FEIN or by an authorized FEIN Serv-
ice Agent, in order to avoid hazardous 
situations.

Have a dust-technical inspection car-
ried out at least once every year by 
the manufacturer or an instructed 
person, e. g., for damage of the filter, 
function and tightness against leakage 
of the vacuum cleaner.
For category L vacuum cleaners that 
were in contaminated environments, 
the exterior as well as all machine 
parts should be cleaned or treated 
with sealants. When performing 
maintenance and repair work, all con-
taminated components that cannot be 
cleaned to satisfactory must be dis-
posed of. Such components must be 
disposed of in impermeable plastic 
bags conforming with the valid regula-
tions for the disposal of such waste.
For maintenance on behalf of the user, 
the vacuum cleaner must be disassem-
bled, cleaned and maintained as far as 
feasible, without causing a risk for the 
maintenance personnel or other per-
sons. Prior to disassembly, the vac-
uum cleaner should be cleaned in 
order to prevent any risks.
The room/enclosure in which the vac-
uum cleaner is disassembled should 
be well ventilated. Wear personal 
protective equipment during mainte-
nance. After the maintenance, the 
maintenance area should be cleaned.
The current spare parts list for this 
vacuum cleaner can be viewed on the 
Internet at www.fein.com.

If required, you can change the fol-
lowing parts yourself:

Fleece filter bag, flat-fold filter, filter 
cartridge, hose, tool sleeve

OBJ_BUCH-0000000148-001.book  Page 29  Tuesday, February 25, 2014  12:35 PM

Содержание Dustex 25L 9 20 27

Страница 1: ...EN 55014 EN 61000 3 2 EN 61000 3 3 2011 65 EU 2006 95 EG 2004 108 EG FEIN Service C E FEIN GmbH Hans Fein Stra e 81 D 73529 Schw bisch Gm nd Bargau www fein com Dustex 25L 9 20 27 Dustex 35L 9 20 28 H...

Страница 2: ...3 33 33 l s 68 72 72 72 72 hPa 213 253 253 253 253 kg 8 6 8 6 8 6 8 6 8 6 LpA dB 68 68 68 68 68 KpA dB 2 2 2 2 2 LwA dB 81 81 81 81 81 h m s2 2 5 2 5 2 5 2 5 2 5 Ka m s2 0 2 0 2 0 2 0 2 0 2 IPX4 IPX4...

Страница 3: ...3 33 33 l s 68 72 72 72 72 hPa 213 253 253 253 253 kg 9 6 9 6 9 6 9 6 9 6 LpA dB 68 68 68 68 68 KpA dB 2 2 2 2 2 LwA dB 81 81 81 81 81 h m s2 2 5 2 5 2 5 2 5 2 5 Ka m s2 0 2 0 2 0 2 0 2 0 2 IPX4 IPX4...

Страница 4: ...123 lv 217 it 39 sk 130 zh CM 225 nl 47 pl 138 zh CK 231 es 54 ro 147 ko 237 pt 62 sl 155 th 244 el 70 sr 162 ja 250 da 79 hr 169 hi 258 no 86 ru 176 ar 272 sv 93 uk 186 fi 100 bg 194 OBJ_BUCH 0000000...

Страница 5: ...5 15 14 13 8 6 9 10 8 8 7 9 10 8 7 12 13 11 OBJ_BUCH 0000000148 001 book Page 5 Tuesday February 25 2014 12 35 PM...

Страница 6: ...6 1 2 2 1 OBJ_BUCH 0000000148 001 book Page 6 Tuesday February 25 2014 12 35 PM...

Страница 7: ...7 1 3 2 1x OBJ_BUCH 0000000148 001 book Page 7 Tuesday February 25 2014 12 35 PM...

Страница 8: ...8 OBJ_BUCH 0000000148 001 book Page 8 Tuesday February 25 2014 12 35 PM...

Страница 9: ...9 1 1 2 2 OBJ_BUCH 0000000148 001 book Page 9 Tuesday February 25 2014 12 35 PM...

Страница 10: ...10 1 2 3 4 OBJ_BUCH 0000000148 001 book Page 10 Tuesday February 25 2014 12 35 PM...

Страница 11: ...11 CLICK 1 3 2 2 1 3 3 OBJ_BUCH 0000000148 001 book Page 11 Tuesday February 25 2014 12 35 PM...

Страница 12: ...12 2 1 OBJ_BUCH 0000000148 001 book Page 12 Tuesday February 25 2014 12 35 PM...

Страница 13: ...13 CLICK 1 2 2 OBJ_BUCH 0000000148 001 book Page 13 Tuesday February 25 2014 12 35 PM...

Страница 14: ...14 OBJ_BUCH 0000000148 001 book Page 14 Tuesday February 25 2014 12 35 PM...

Страница 15: ...15 1x 3x OBJ_BUCH 0000000148 001 book Page 15 Tuesday February 25 2014 12 35 PM...

Страница 16: ...y of the power tool with the direc tives of the European Community Confirms the conformity of the power tool with the Guide lines of the European Customs Union General prohibition sign This action is...

Страница 17: ...tional Explanation P1 W W Power input PA W W Max connected load of the integrated socket outlet U V V Rated voltage f Hz Hz Frequency l l Container capacity l l Capacity for liquids l s l s Air flow w...

Страница 18: ...s Appropriate protective equip ment is required Do not operate the vacuum cleaner without the complete filter system Otherwise there is dan ger to your own health This vacuum cleaner is also suitable...

Страница 19: ...not drive over or pinch the power supply cord Dam aged or entangled power supply cords increase the risk of an electric shock Before replacing accessories pull the mains plug from the socket outlet T...

Страница 20: ...ag seal it with the closing cover in order to avoid debris For vacuuming dusts of dust cate gory L only dry flat fold filters which have not been moist or wet are permitted to be used Before switching...

Страница 21: ...ations Have a dust technical inspection car ried out at least once every year by the manufacturer or an instructed person e g for damage of the filter function and tightness against leakage of the vac...

Страница 22: ...e sorted for environment friendly recycling Malfunction Cause Troubleshooting Vacuum cleaner can not be switched on Circuit breaker of power connection has tripped Ensure power supply Vacuum cleaner i...

Отзывы: