2.4 How to charge the accumulator
The 9V-accumulator may be charged with the accompanying plug power pack. The accumulator may remain
in the battery compartment for charging. The plug power pack, which has been adjusted at 12V=, feeds the
charging connection with a 3,5mm-jack bush. It is not necessary to switch on the diagnostic device in order to
start the charging process. The accumulator needs approx. 14 hours until it is fully charged.
Warning:
In case of power pack operation, a conventional 9V-block battery has to be removed from the
battery compartment. Otherwise there is danger of destruction !
Polarity at the 3,5mm-jack bush:
-
+
The 9V-accumulator may also be charged with an external battery charger.
3 Technical Data
Power supply
9V accumulator or
12V DC plug power pack
Service life
Akku Varta 5022
approx. 3 hours
Charging
Conventional battery charger by removing the accumulator
or directly with power pack 12V DC via charging bush,
total charging 14 h
Temperature range
0 to 50°C
Storage temperature
-20 to 50°C
Measuring range
10 - 150 kHz
Measuring accuracy
+/- 1 Digit
Display
LCD 1 x 16 Character
Housing
Plastic housing with battery compartment
30 x 80 x 150 (H x B x L)
Weight
190 g (without battery)
Protection class
IP 40