FUZ2 -A/-B/-C/-CX/-G/-L
Assembly instructions
TST
FEIG ELECTRONIC GmbH
Page 94 of 96
TST_FUZ2-A-B-C-CX-G-L_Montageanleitung_EN_22.docx
15 Specifications
Dimensions (W x H x D)
Dimensions board set (L x W x H):
approx. 270 x 195 x 150 mm to frame with quick release
incl. heatsink
excl. extension boards as TST RFUxK or TST RFUxCom
Controller variants -A / B
182 x 328 x 102 mm (with spacers)
Controller variants -C / -CX
182 x 328 x 121 mm
Controller variants
-CGH / -CXGH / -LGH
210 x 430 x 200 mm
incl. heatsink, brake resistor & wall mounts
excl. cable entries (L +20 mm) and main switch (H +35 mm)
Dimensions plastic housing
(H x W x D)
approx. 430 x 210 x 200 mm
incl. heatsink, brake resistor & wall mounts
excl. cable entries (L +20 mm) and main switch (H+ 35 mm)
Dimension steel or stainless steel
housing
approx. 300 x 476 x 218 mm
approx. 400 x 676 x 218 mm
approx. 600 x 676 x 218 mm
excl. cable entries (L +20 mm) , main switch and
emergency stop button (H+ 35 mm)
Hygiene housing dimensions
approx. 444 x 549 x 210 mm
excl. cable entries (L +20 mm) , main switch and
emergency stop button (H+ 35 mm)
Installation
vertically via the wall bracket on the housing bottom
Supply voltage over
L, N, PE
230 V
AC
10%, 50...60 Hz
permissible range: 110...240 V ± 10% / 50...60 Hz
Protection: 16 A K-characteristic
Controller idling current
max. 30 W when fully configured
External power supply (depending
on network): Terminal L1
According to supply voltage to terminal L
(secured on the circuit board: F200 / 4AT)
Control voltage / external supply 2
24 V
DC
regulated (
10% at nominal voltage 230 V)
Controller variant -A:
max. 250 mA
Controller variants -B/-C/-CX/-CGH/-CXGH/-LGH:
max.
500 mA
ncl. optional plug-in modules. Fuse protected by means of
self-resetting semiconductor fuse.
Short-circuit protected by central switching regulator.
Control voltage / external supply 3
for electronic limit switches and Safety edge
Nominal value 11.3V / max. 130mA
Controller inputs
Inputs 1
– 10 in
Controller variants
-C / -CX / -CGH / -CXGH / -LGH
Inputs 1
– 9 in
Controller variant -A
24 VDC / typ.15 mA, max 26 VDC / 20 mA.
all inputs are potential free to join or:
< 2 V: inactive
à
logical 0
>10.5 V: active
à
logical 1
min. Duration of input control commands: >
100 ms
Galvanic isolation using on-board opto-couplers
Input IN10
Controller variant -B
Evaluation for slip door switch with 8.
2 kΩ termination
resistor or is used as a second safety edge monitor.
Serial interface
RS485 A and B
only for electronic limit switches
RS485 level, terminated in 100 Ω
Safety chain / Emergency STOP
Terminals:
E-Stop ext.31/32
and
41/42
all inputs must be connect free of potential
Contact rating:
26 V
DC
/
120 mA
in case the safety chain is interrupted, the drive cannot be
moved, not even under Deadman conditions
Not jumpered from the factory
Safety edge input:
For electrical safety edges with 1.2 or 8.2 kΩ terminating
resistor and for dynamic optical systems