Faults in the safety chain
F.385
Fault in pre-limit switch for
safety edge
•
Pre-limit switch for turning off the safety edge or reversing
after safety edge tripping remains tripped even in the upper
end position.
General hardware faults
F.400
Controller hardware reset
detected
•
Excessive noise on supply voltage
•
Internal watchdog tripped
•
RAM
error
F.410
Over-current (motor current or
intermediate circuit)
•
Wrong motor data set (P100 – P103)
•
Non-adjusted voltage increase / boost set (P140 or P145)
•
Motor not properly dimensioned for door
•
Door
sticks
F.420
Overvoltage in intermediate
circuit Limit 1
•
Brake chopper interference / defective / missing
•
Feed voltage much to high
•
Motor feeds back too much energy in generator mode, door
motion energy cannot be sufficiently brought down
F.430
Temperature cooler outside of
working range Limit 1
•
Excessive load on final stages or brake chopper
•
Ambient temperature too low for controller operation
•
Clock frequency of final stage too high (Parameter
P.160
)
F.440
Overcurrent in intermediate
circuit Limit 1
•
Boost not adjusted
•
Motor incorrectly dimensioned for door
•
Door
sticks
F.510
Motor / intermediate circuit
overcurrent Limit 2
•
Wrong motor data set (P100 – P103)
•
Non-adjusted voltage increase / boost set (P140 or P145)
•
Motor not properly dimensioned for door
•
Door
sticks
F.515
Motor protection function
detected overcurrent
•
Incorrect motor curve (motor rated current) set (P101)
•
Too much boost (P140 or P145)
•
Motor incorrectly dimensioned
F.519
IGBT driver chip detected
overcurrent
•
Short circuit or ground fault on motor terminals
•
Motor rated current setting extremely wrong (P100)
•
Extremely too much boost (P140 or P145)
•
Motor incorrectly dimensioned
•
Motor
winding
defective
•
Momentary interruption of the E-Stop circuit.
F.520
Overvoltage in intermediate
circuit Limit 2
•
Brake chopper interference / defective / missing
•
Feed voltage much to high
•
Motor feeds back too much energy in generator mode, door
motion energy cannot be sufficiently brought down.
F.521
Overvoltage in intermediate
circuit
•
Input voltage supply too low, usually at load
•
Load too great / final stage or brake chopper fault