manualshive.com logo in svg
background image

 

MONTAGE  

INSTALLATION 

 

final 

public (B) 

2012-03-08 

M70201-4de-ID-B.doc 

 

   

ID ISC.MRU200 

MidRange Reader UHF 

 

 

 

 

(deutsch / english) 

 

Содержание OBID i-scan UHF ISC.MRU200

Страница 1: ...MONTAGE INSTALLATION final public B 2012 03 08 M70201 4de ID B doc ID ISC MRU200 MidRange Reader UHF deutsch english...

Страница 2: ...OBID i scan Montage ID ISC MRU200 FEIG ELECTRONIC GmbH Seite 2 von 52 M70201 4de ID B doc D E U T S C H deutsche Version ab Seite 3 english version from page 28 E N G L I S H...

Страница 3: ...Wissen und Gewissen FEIG ELECTRONIC GmbH bernimmt keine Gew hrleistung f r die Richtigkeit und Vollst ndigkeit der An gaben in diesem Dokument Insbesondere kann FEIG ELECTRONIC GmbH nicht f r Folgesch...

Страница 4: ...9 3 2 Dichtverschl sse 9 3 3 Deckelhalter 10 3 4 Designblenden 10 4 Anschlussklemmen und buchsen 11 4 1 Versorgungsspannung 12 4 2 Antennenanschl sse 13 4 3 Schnittstellen 14 4 3 1 RS232 Schnittstelle...

Страница 5: ...G ELECTRONIC GmbH Seite 5 von 52 M70201 4de ID B doc D E U T S C H 5 3 J1 J8 Schnittstellenkonfiguration 22 5 4 X62 Bootloader Modus 23 6 Technische Daten 24 6 1 Zulassung 26 6 1 1 Europa CE 26 6 1 2...

Страница 6: ...ne ungeeignete falsche manuelle oder automatische Einstellung von Parametern f r ein Ger t bzw ungeeignete Verwendung eines Ger tes wird keine Haftung bernommen Reparaturen d rfen nur vom Hersteller d...

Страница 7: ...Readertypen Readertyp Beschreibung ID ISC MRU200 USB EU Reader mit USB Schnittstelle f r Europa ID ISC MRU200 E EU Reader mit Ethernet Schnittstelle f r Europa ID ISC MRU200 USB FCC Reader mit USB Sc...

Страница 8: ...Art der Schrauben und Befestigungsd bel h ngt stark von der Festigkeit des Untergrundes ab Die D bel und Schrauben sollten mindestens eine zul ssige Last von 1 5 kN f r alle Belastungsrichtungen aush...

Страница 9: ...nge 4 M 12 3 5 7 Schnittstelle seriell 5 M 12 3 5 7 Spannungsversorgung 6 M 25 9 17 Ethernet Interface nur E USB nur A 3 2 Dichtverschl sse Mit denen im Zubeh r beigelegten Dichtverschl ssen k nnen n...

Страница 10: ...an dem Geh use fixiert werden Die Deckelhalter werden in die daf r vorgesehenen ffnungen eingesteckt Bild 3 3 Deckelhalter 3 4 Designblenden Die Designblenden werden nach der Montage des Readers aufg...

Страница 11: ...nd buchsen In Bild 4 1 und Bild 4 2 sind alle Anschlussklemmen und buchsen sowie die Bedien und Anzei geelemente f r die Readertypen USB bzw E dargestellt Bild 4 1 Anschlussklemmen und buchsen Typ A T...

Страница 12: ...zeichen Beschreibung X1 Pin 1 VDC VDC Versorgungsspannung X1 Pin 2 GND Ground Versorgungsspannung Bild 4 3 Anschluss der Versorgungsspannung Die Ausgangsleistung des Netzteils sollte min 15 W betragen...

Страница 13: ...tennen erfolgt ber die SMA Buchsen ANT1 und ANT2 Das SWR der ange schlossen Antennen mit Kabel darf 1 5 1 nicht berschreiten Tabelle 4 2 Antennenanschluss Anschluss Beschreibung ANT1 ANT2 SMA Buchse f...

Страница 14: ...X2 Die bertragungsparameter k nnen per Softwareprotokoll konfiguriert werden Tabelle 4 3 Pinbelegung RS232 Schnittstelle Klemme Kurzzeichen Beschreibung X2 Pin 1 GND RS232 GND X2 Pin 2 RxD RS232 RxD...

Страница 15: ...5 3 J1 J8 Schnittstellenkonfiguration Der Anschluss der RS485 bzw RS422 Schnittstelle erfolgt ber X3 Tabelle 4 4 zeigt die Pinnbelegung f r die entsprechende Schnittstelle Tabelle 4 4 Pinbelegung RS48...

Страница 16: ...TX Transmit Data X7 Pin 2 TX Transmit Data X7 Pin 3 RX Receive Data X7 Pin 4 VETH n c X7 Pin 5 VETH n c X7 Pin 6 RX Receive Data X7 Pin 7 VETH n c X7 Pin 8 VETH n c Vorraussetzung f r den Einsatz des...

Страница 17: ...e X5 sind galvanisch von der Reader Elektronik getrennt und m ssen daher mit einer externen Gleichspannung versorgt werden Die Eingangs LEDs der Optokoppler sind intern mit einem Serienwiderstand Rint...

Страница 18: ...1 24 V 820 Hinweise Die Eing nge sind f r eine maximale Eingangsspannung von 24 VDC und einen Ein gangsstrom von maximal 20 mA ausgelegt Verpolung oder berlastung der Eing nge f hrt zu deren Zerst run...

Страница 19: ...m ssen daher mit einer externen Spannung betrieben werden Tabelle 4 9 Pinbelegung Optokopplerausg nge Klemme Kurzzeichen Beschreibung X4 Pin 1 O1 C Kollektor Ausgang 1 X4 Pin 2 O1 E Emitter Ausgang 1...

Страница 20: ...emme Kurzzeichen Beschreibung X6 Pin 1 COM Arbeitskontakt X6 Pin 2 NC ffner X6 Pin 3 NO Schlie er Bild 4 9 Interne und m gliche externe Beschaltung des Relaisausgangs Hinweise Der Relaisausgang ist f...

Страница 21: ...ein kurzes Blinken die fehlerfreie Kommunikation mit einem Transponder auf der RF Schnittstelle Blinkt abwechselnd mit V1 nach dem Reset im Anschluss an ein Software Update Blinkt abwechselnd mit V1...

Страница 22: ...zugeschaltet werden Tabelle 5 3 Abschlusswiderst nde der RS485 RS422 Jumper Geschlossen offen J1 Pull Up an RS4xx B ohne Pull Up an RS4xx B J2 Pull Down an RS4xx A ohne Pull Down an RS4xx A J5 Abschlu...

Страница 23: ...der Modus Die Stiftleiste X62 kann mit einem Jumper Rasterma 2 0 mm kurzgeschlossen werden In Ta belle 5 4 ist die Funktion der Stiftleiste X62 beschrieben Tabelle 5 4 Stiftleiste X62 X60 Beschreibung...

Страница 24: ...gsversorgung 12 24 VDC 5 Noise Ripple max 150 mV Leistungsaufnahme max 15 VA Betriebsfrequenz 865 6 867 6 MHz EN 302 208 902 928 MHz FCC CFR 47 Part 15 247 Sendeleistung 100 300 mW 100 mW Step Softwar...

Страница 25: ...ose des Betriebszustandes Multi Reader Betrieb Synchronisation der Luftprotokolle durch Ver wendung der Reader Synchronisation Umgebungsbedingungen Temperaturbereich Betrieb Lagerung 25 55 C 25 85 C V...

Страница 26: ...at may cause undesired operation NOTICE Changes or modifications made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment This equ...

Страница 27: ...radiated power EIRP is not more than that permitted for successful communication This device has been designed to operate with the antennas listed below and having a maximum gain of 10 5 dBic Antennas...

Страница 28: ...on in this manual has been done to the best of our knowledge FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for...

Страница 29: ...stallation 33 3 1 Cable Glands 34 3 2 Seal Caps 34 3 3 Cover stays 35 3 4 Decorative Covers 35 4 Terminals and Jacks 36 4 1 Supply Voltage 37 4 2 Antenna Connections 38 4 3 Interfaces 39 4 3 1 RS232 I...

Страница 30: ...00 FEIG ELECTRONIC GmbH Page 30 of 52 M70201 4de ID B doc E N G L I S H 5 3 J1 J8 Interface configuration 47 5 4 X62 Boot Loader Mode 48 6 Technical Data 49 6 1 Approval 51 6 1 1 Europe CE 51 6 1 2 US...

Страница 31: ...or the device The manufacturer shall not be held legally responsible for inaccuracies errors or omissions in the manual or automatically set parameters for a device or for an incorrect application of...

Страница 32: ...urrently available Table 2 1 Available Reader types Reader type Description ID ISC MRU200 USB EU Reader with USB Interface for Europe ID ISC MRU200 E EU Reader with Ethernet Interface for Europe ID IS...

Страница 33: ...The size and type of the screw anchors depends considerably on the strength of the wall The anchors should be capable of withstanding a permissible load of at least 1 5 kN per anchor for all load dir...

Страница 34: ...0 0 18 0 39 Inputs Relay Outputs 4 M 12 3 5 7 0 14 0 28 Interface serial 5 M 12 3 5 7 0 14 0 28 Supply voltage 6 M 25 9 17 0 35 0 67 Ethernet Interface Model E only USB Interface Model USB only 3 2 Se...

Страница 35: ...ed to attach the cover to the housing The cover stays are inserted into the openings provided for this purpose Fig 3 3 Cover stay 3 4 Decorative Covers The decorative covers are attached after install...

Страница 36: ...minals and Jacks Fig 4 1 and Fig 4 2 show terminals jacks and operating elements of reader type USB respective ly reader type E Fig 4 1 Terminals jacks and operating elements of Type USB T1 K1 X6 X5 X...

Страница 37: ...y voltage pin assignments Terminal Abbreviation Description X1 Pin 1 VDC Vcc supply voltage X1 Pin 2 GND Ground supply voltage Fig 4 3 Connecting the supply voltage The output power of the power suppl...

Страница 38: ...the SMA jacks ANT1 and ANT2 The SWR of the con nected antennas with the cables should not be worse than 1 5 1 Table 4 2 Antenna Connections ANT1 and ANT2 Connections Description ANT1 ANT2 SMA jacks f...

Страница 39: ...n X2 The transmission parameters can be configured by means of software protocol Table 4 3 RS232 interface pinouts Terminal Abbreviation Description X2 Pin 1 GND RS232 GND X2 Pin 2 RxD RS232 RxD X2 Pi...

Страница 40: ...n be configured for RS485 or RS422 see 5 3 J1 J8 Inter face configuration The RS485 interface respectively RS422 interface is connected to X3 Table 4 4 RS485 RS422 interface pinouts Terminal Abbreviat...

Страница 41: ...Data X7 Pin 2 TX Transmit Data X7 Pin 3 RX Receive Data X7 Pin 4 VETH n c X7 Pin 5 VETH n c X7 Pin 6 RX Receive Data X7 Pin 7 VETH n c X7 Pin 8 VETH n c The prerequisite for using TCP IP protocol is...

Страница 42: ...puts in Terminal X5 are galvanically isolated from the Reader electronics and must therefore be externally supplied The input LEDs for the optocouplers are switch internally with a series resistor Rin...

Страница 43: ...series resistor Rext 5 10 V 11 15 V 270 16 20 V 560 21 24 V 820 Notes The inputs are configured for a maximum input current of 24 VDC and an input current of maximum 20 mA Reversing the polarity or ov...

Страница 44: ...must therefore be powered with an external power supply Table 4 9 Optocoupler output pin configuration Terminal Abbreviation Description X4 Pin 1 O1 C Collector Output 1 X4 Pin 2 O1 E Emitter Output...

Страница 45: ...ion Description X6 Pin 1 COM Working contact X6 Pin 2 NC Normally closed X6 Pin 3 NO Normally open Fig 4 9 Internal and possible external wiring of the relay output Notes The relay outputs are configu...

Страница 46: ...flashing indicates errorless communication with a transponder on the RF interface Flashes alternately with V1 after a reset following a software update Flashes alternately with V1 in case of a data er...

Страница 47: ...Termination resistors for RS485 RS422 Jumper closed open J1 Pull Up on RS4xx B without Pull Up on RS4xx B J2 Pull Down on RS4xx A without Pull Down on RS4xx A J5 Termination resistor RS4xx A RS4xx B w...

Страница 48: ...age 48 of 52 M70201 4de ID B doc E N G L I S H 5 4 X62 Boot Loader Mode The pin connector X62 can be closed with a jumper 2 0 mm Table 5 4 pin connector X62 X62 Description open no effect closed after...

Страница 49: ...age 12 24 VDC 5 Noise Ripple max 150 mV Power Consumption max 15 VA Operating Frequency 869 525 MHz EN 300 220 865 6 867 6 MHz EN 302 208 902 928 MHz FCC CFR 47 Part 15 247 Transmitting Power 100 300...

Страница 50: ...perating status diagnostics Multi Reader Operation Synchronization of the air protocols using Reader synchronization Ambient Temperature range Operating Storage 25 55 C 13 131 F 25 85 C 13 185 F Vibra...

Страница 51: ...y cause undesired operation NOTICE Changes or modifications made to this equipment not expressly approved by FEIG ELECTRONIC GmbH may void the FCC authorization to operate this equipment This equipmen...

Страница 52: ...y radiated power EIRP is not more than that permitted for successful communication This device has been designed to operate with the antennas listed below and having a maximum gain of 10 5 dBic Antenn...

Отзывы: