8.1.6. [0x25] Select
This command sets one Transponder to the Select State. Only one ISO15693 Transponder can be
selected at once. An already selected Transponder will automatically be set to Ready State.
REQUEST-DATA
6
7
8...15
0x25
MODE
UID
RESPONSE-DATA (STATUS = 0x95)
7
ISO15693
ERROR
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
ADR
ADR:
b001
addressed
UID:
Read-only UID of the Transponder.
ISO15693 ERROR:
ISO15693 ERROR code of Transponder response. This byte is only available if STATUS
= 0x95.
Note:
•
This command is only available for ISO15693 Transponders.