background image

OBID

 

 i-scan

® 

HF 

Installation 

ID ISC.M02 

 

FEIG ELECTRONIC GmbH 

Page 5 of 27 

M20301-4e-ID-B.doc 

 

Safety Instructions / Warning - Read before start-up ! 

  The device may only be used for the purpose intended by the manufacturer. 

  The operation manual should be kept readily available at all times for each user. 

  Unauthorized changes and the use of spare parts and additional devices which have not been 

sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such 
unauthorized measures shall exclude the manufacturer from any liability. 

  The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid 

for the device. The manufacturer shall  not be held legally responsible for inaccuracies, errors, 
or omissions in the manual or automatically set parameters for a device or  for an incorrect 
application of a device. 

  Repairs may only be undertaken by the manufacturer. 

  Installation, operation, and maintenance procedures should only be carried out by qualified 

personnel. 

  Use of the device and its installation must be in accordance with national legal requirements 

and local electrical codes . 

  When working on devices the valid safety regulations must be observed. 

  Before touching the device, the power supply must always be interrupted. Make sure that the 

device is without voltage by measuring. The fading of an operation control (LED) is no indicator 
for an interrupted power supply or the device being out of voltage! 

  Special advice for wearers of cardiac pacemakers: 

Although this device doesn't exceed the valid limits for electromagnetic fields you should keep 
a minimum distance of 25 cm between the device and your cardiac pacemaker and not stay in 
the immediate proximity of the device’s antenna for any length of time. 

 

Содержание OBID i-scan ID ISC.M02

Страница 1: ...INSTALLATION MANUAL final public B 2016 03 17 M20301 4e ID B doc ID ISC M02 English...

Страница 2: ...useful tips The instructions given in this manual are based on advantageous boundary conditions FEIG ELECTRONIC GmbH does not give any guarantee promise for perfect function in cross environments and...

Страница 3: ...3 2 1 Supply voltage 10 3 2 2 RS232 interface TTL 11 3 2 3 Data Clock interface 12 3 2 4 Optional Security Module ID SAM M02 13 3 3 Display elements 14 3 4 Operating elements 15 3 4 1 Operating Progra...

Страница 4: ...OBID i scan HF Installation ID ISC M02 FEIG ELECTRONIC GmbH Page 4 of 27 M20301 4e ID B doc 4 3 2 Canada IC approved antennas 24 4 4 Label Information Reader ID ISC M02 B 25 5 Technical Data 26...

Страница 5: ...tically set parameters for a device or for an incorrect application of a device Repairs may only be undertaken by the manufacturer Installation operation and maintenance procedures should only be carr...

Страница 6: ...is designed for reading and writing passive transponders so called Smart Labels with an operating frequency of 13 56 MHz It is suitable for any application in which short read ranges and small reader...

Страница 7: ...mm 3 94inch x 3 94inch ID ISC ANT40 30 A PCB Antenna 50 40mm x 30mm 1 57inch x 1 57inch 2 3 Scope of delivery The following components are included Module type Included ID ISC M02 B 1 x Reader Module...

Страница 8: ...M20301 4e ID B doc 3 Installation and wiring 3 1 Dimensions Fig 1 shows the dimensions of the ID ISC M02 Reader Module in mm Fig 1 Dimensions of the ID ISC M02 Reader Module in mm 26 1 2 1 3 3 3 3 3 3...

Страница 9: ...X1 Pin no Function Description ID ISC M02 B 1 DAT Data line for the data clock interface 2 CLK Clock line for the data clock interface 3 TxD RS232 TTL Transmit Data 4 GND GND 5 RxD RS232 TTL Receive...

Страница 10: ...equate filtering Noise from the power supply can result in a reduction of the read write range of the module The cable length from the power supply should be as short as possible and should in any cas...

Страница 11: ...er Module Table 3 Pin assignments for the RS232 interface on X1 The transmission parameters for the interface can be software configured Table 4 shows the standard parameters for the RS232 interface P...

Страница 12: ...X1 Pin no Function Description ID ISC M02 B 1 DAT Data line for the data clock in terface 2 CLK Clock line for the data clock interface 7 CLS CLS line for the data clock in terface 4 9 GND GND GND Pin...

Страница 13: ...optional ID SAM M02 Security Module can be connected to terminals X3 and X4 The ID SAM M02 Security Module provided additional security by using cryptographic data trans mission between the reader an...

Страница 14: ...ions of both LEDs can be configured using software protocol It is also possible to control both LEDs directly using an additional software protocol Table 3 3 1 shows the standard setting for V1 and V2...

Страница 15: ...r starts after a reset Since the reader s firmware however also has a software bootloader the hardware bootloader option should be used only for installing the software bootloader For additional infor...

Страница 16: ...the internal antenna to the driver circuit of the reader To connect an external antenna both jumpers J2 and J3 must therefore be removed Jumpers J2 and J3 Description in Internal antenna connected ou...

Страница 17: ...scilloscope probe with the probe point and hold it over the circuit board of the ID ISC M02 The probe then forms a measuring loop for the radiated magnetic field of the ID ISC M02 The distance between...

Страница 18: ...the trim capacitor Beschriftung Minimale Kapazit t Maximale Kapazit t Fig 10 Minimum and maximum position of the trim capacitor C65 After the antenna has bee tuned check it again for maximum range and...

Страница 19: ...stances for the reader The distance between the reader and a metal surface should be at least 3 cm Note that even other circuit boards may act line metal objects depending on how much copper they cont...

Страница 20: ...ion of a magnetic field alternating magnetic fields in the vicinity of the an tenna can have a negative impact on its function Sources of such magnetic interference fields include coils within a prima...

Страница 21: ...4e ID B doc 4 Radio Approvals 4 1 Europe CE When used according to regulation this radio equipment conforms with the basic requirements of Article 3 and the other relevant provisions of the R TTE Guid...

Страница 22: ...OBID i scan HF Installation ID ISC M02 FEIG ELECTRONIC GmbH Page 22 of 27 M20301 4e ID B doc 4 2 Declaration of Conformity...

Страница 23: ...ot installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful inte...

Страница 24: ...identify the device by certification number or model number if Category II has been approved by Industry Canada to operate with the antenna types listed below with maxi mum permission gain and requir...

Страница 25: ...scan HF Installation ID ISC M02 FEIG ELECTRONIC GmbH Page 25 of 27 M20301 4e ID B doc 4 4 Label Information Reader ID ISC M02 B The following label is positioned on the backside of the reader ID ISC...

Страница 26: ...7 x 1 97 x 0 55 inch Weight 14g 0 03lb Connector 10 Pin Connector spacing 2 54mm 0 1inch Electrical Data Supply voltage ID ISC M02 B 5 V DC 5 Current draw max 200mA Power consumption max 1 Watt Operat...

Страница 27: ...e 1 Code UID I Code EPC with separate firm ware and Upgrade Code ISO18000 3M3 with separate firmware and Upgrade Code EEPROM for parameters 1 kB 10 000 write cycles FLASH 64 kB for Parameter firmware...

Отзывы: