3.2.1 X1: Reader connection and supply voltage
The HF line and the supply voltage are connected as shown in Fig. 5 at SMA socket X1. The
dynamic antenna tuner operates on a DC voltage of 7 - 12V.
Fig. 5: HF line and supply voltage connection
The supply voltage of 7 –12 V
DC
is present as a DC voltage offset on the HF line. See also
3.2.2 X2: Boot Loader Interface
To perform a firmware update you have to connect the update cable ID CAB.RS-B with X2 as
shown in Fig. 6. The tuning board must be powered through the antenna cable on X1 as it is done
in the normal operation mode. See also
Fig. 6: Connection of the Update Cable
The procedure of the firmware update is described in Application Note
ID ISC.DAT – Firmware
Update
(N50801-xe-ID-B).