![Feig Electronic OBID i-scan ID ISC.ANT.UMUX Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/feig-electronic/obid-i-scan-id-isc-ant-umux/obid-i-scan-id-isc-ant-umux_firmware-update_3926711006.webp)
OBID
i-
scan
®
Application-Note
ID ISC.ANT.UMUX
FEIG ELECTRONIC GmbH
Page 6 of 10
N80301-1e-ID-B.doc
2.1. Detection of the Antenna Multiplexer
1. Enable the COM-Port and select the used COM-port. The Bus Address has to be set to 0.
2.
Press the “Detect” button. The connected tuning board is displayed in the list.
3.
Press the “Next” button.
Note:
By using a notebook or an USB to RS232 converter see application note for OBID Firm-
ware Update Tool (N30300-2e-ID-B).