![Feig Electronic OBID i-scan HF LRM2500 Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/feig-electronic/obid-i-scan-hf-lrm2500/obid-i-scan-hf-lrm2500_installation-manual_3859275033.webp)
OBID
i-scan
®
HF
Installation
LRM2500
FEIG ELECTRONIC GmbH
Seite 33 von 69
M00910-8e-ID-B-ANATEL.doc
LAN / TCP/IP
The Reader has an integrated 10 / 100 Base-T network port for an RJ-45. Connection is made on
X1 and has an automatic “Crossover Detection” according to the 1000 Base-T Standard.
With structured cabling shielded CAT-5 cables should be used. This ensures a reliable operation at
10 Mbps or 100 Mbps.
The prerequisite for using TCP/IP protocol is that each device has a unique address on the net-
work. All Readers have a factory set IP address.
Network
Address
IP-Adresse
192.168.10.10
Subnet-Mask
255.255.255.0
Port
10001
DHCP
OFF
Table 9 Standard factory configuration of the Ethernet connection
Note:
The Reader TCP/IP interface has a DHCP option.
More Information about the interfaces you will find in the manual
M01111-xde-ID-B
of the reader.
X1
Figure 2: LAN interface for host communication