4. Technical data
ID CPR.02.VP/AB-A
ID CPR.02.VP/AB-B
Housing
Plastic material ASA
Color
bottom part
top part
similar to RAL 9002 (greyish white)
similar to RAL 7043 (traffic grey)
Weight
approx. 120 g
Protection class
IP 54
Supply Voltage
12 - 24 V AC/DC
Power consumption
max. 2,6 W
Temperature range
Operation
storage
-25 °C to +60 °C
-40 °C to +85 °C
Relative air humidity
95 % (non-condensing)
Antenna
internal (aprox. 70 x 70 mm)
Operating frequency
13,56 MHz
RF Transmitting Power
250 mW
±
2 dB
Supported Transponder types
•
ISO14443-A compatible
(e. g. mifare, mifare Ultra Light, my-d proximity)
•
ISO14443-B compatible
•
ISO15693 compatible
(e. g. I
•
Code SLI, Tag-It HFI, my-d vicinity, STM LRI512)
•
I
•
Code 1
LED
bicolor (red, green, orange)
Buzzer
integrated
Relay
-
1 x normaly open
(capacity of contacts:
24 V AC/DC 1,5 A)
Digital inputs
3
(lead in wire max. 3 m)
2
(lead in wire max. 3 m)
4800 to 38400 Baud
asynchronous
RS232
(lead in wire max. 10 m)
RS485
(max. 32 units on
each data bus)
Interfaces
Data / Clock
TTL
(lead in wire max. 3 m)
•
Magnetic Stripe Emulation
•
Wiegand-Emulation
-
DIP-switch
8-chanel
Flash
64 kB (In-Application Firmwareupdate )
EEPROM
512 B (10.000 writing cycles)
Default values (factory alined):
asynchronous interface:
38400 Baud, 8 data- 1 stopbit, even parity
•
orange blinking (no active connection to host-computer)
LED-operation control
•
orange (active connection to host-computer is active)