![Feig Electronic ID RWA12.ABC-A Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/feig-electronic/id-rwa12-abc-a/id-rwa12-abc-a_mounting-instruction_548876025.webp)
Installation Manual ID RWA12.ABC-A / -B
FEIG ELECTRONIC GmbH
Page 25 of 28
E N G L I S H
5.2 LED- and beeper Signals
Mode
signal
description
MasterCard-Mode
200 ms each:
«
red
Õ
off
Õ
green
Õ
off
¯
multijob-Reader
waits for
OBID
®
MasterCard
1 x 800 ms
green + beeper
OK:
OBID
®
MasterCard has been read in and
stored
300 ms each:
«
red + beeper
Õ
off
¯
Error:
8 x invalid
OBID
®
MasterCard:
wrong or faulty SYSTEM-ID
9 x CFG-ALLOC checksum error
10 x CFG-ALLOC address-area error
(invalid CFG-EE)
11 x Parameter checksum error
12 x internal EEPROM defect
EE-Init-Mode
520 ms each
«
red
Õ
green
¯
Checksum of an EEPROM-parameter record
(CFG-EE) has been faulty. This (these) has
(have) been initialized with (a) default-value(s).
Offline-Mode
4
yellow flashing
No communication (multijob-Poll) between host
and
multijob-Reader
Online-Mode
5
yellow
communication (multijob-Poll) Host and
multijob-
Reader
exists
4
factory adjustment, may be changed individually.
5
factory adjustment, may be changed individually.