Identification
Installation
ID ISC.MU02.02
FEIG ELECTRONIC GmbH
Page 12 of 22
M91002-5e-ID-B.docx
The transmission parameters for the interface can be software-configured. Table 6 shows the
standard parameters for the RS232 interface.
Table 6: Standard parameters of the RS232 interface
NOTE:
IF there is a RS232 to TTL converter used without external power supply it may be neces-
sary to
switch on the COM Port parameter “RTS” and “DTR” manually.
3.2.3. Data/Clock interface
The length of the cable to the data/clock interface should be kept as short as possible. It must not
exceed 3 m.
Table 7: Pin assignment for the Data/Clock interface at Terminal X2
X2
Pin no.
Function
Description
1
DAT
Data line for the data/clock interface
2
CLK
Clock line for the data/clock interface
7
CLS
CLS line for the data/clock interface
4, 9
GND *
Ground
*
GND-Pins 4 and 9 are to be connected directly to each
other on the Reader Module
Figure 3: Connecting the data/clock interface
Parameter
Standard setting
Baud rate
38400
No. of data bits
8
Parity
Even
No. of stop bits
1