![Feig Electronic ID ISC.MU02.02-CU Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/feig-electronic/id-isc-mu02-02-cu/id-isc-mu02-02-cu_manual_3882212057.webp)
OBID
i-scan
®
UHF
Manual
ID ISC.MU02.02
FEIG ELECTRONIC GmbH
Page 57 of 96
H90701-3e-ID-B
8.2. [0x81] Write Configuration
The configuration of the Reader can be changed by means of the Write Configuration command. In
order to do this, the configuration memory is written with 14 bytes long blocks and addressed by
CFGn in the byte CFG-ADR. The description of parameters can be taken from Chapter 7. Configu-
ration Parameters (CFG)
Host
→
Reader
1
2
3
4
5...18
19-20
20
COM-ADR
[0x81]
CFG-ADR
CFG-REC
CRC16
Host
←
Reader
1
2
3
4
5-6
6
COM-ADR
[0x81]
STATUS
CRC16
CFG-ADR
Bit:
7
6
5
4
3
2
1
0
Function
LOC
0
CFGn: Address of Configuration Block
CFGn:
memory-address of the required configuration block
LOC:
specifies the location of the configuration block
b0
RAM
b1
RAM and EEPROM
CFG-REC:
14 bytes configuration block stored in the configuration memory of the Reader at
address CFGn.
NOTE:
A write configuration to EEPROM with reserved configuration blocks will cause a 0x16 error
code.
8
see ANNEX C: Index of Status Bytes
9
see chapter 7. Configuration Parameters (CFG)