Identification
Manual
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 40 of 153
H01113-4e-ID-B.docx
4.9. CFG11 Read Mode Data
The parameters of the CFG11 configuration block contain Scan Mode settings.
Byte
0
1
2
3
4
5
6
Contents
TR-DATA-1
TR-DATA-2
TR-DATA-3
0x00
DB-ADR
0x00
Default
0x01
0x00
0x00
0x0000
Byte
7
8
9
10
11
12
13
Contents
0x00
DB-N
0x00
D-START
D-LGT
Default
0x0001
0x00
0x0004
Note:
Changing of parameter only becomes effective after writing / saving configura-
tion block CFG12 to EEPROM and reset of the RF Controller with
TR-DATA-1:
Selects the data types for read operation.
Bit:
7
6
5
4
3
2
1
0
Function
Exten-
sion
0
TIMER
0
Byte
Order
DB
0
DB
SNR
SNR
…
(OperatingMode.NotificationMode.DataSelector.UID)
(OperatingMode.ScanMode.DataSelector.UID)
b0:
no Serial Number will be stored
b1:
Serial Number will be stored
DB
(OperatingMode.NotificationMode.DataSelector.Data)
(OperatingMode.ScanMode.DataSelector.Data)
b0:
no data block will be stored
b1:
data block will be stored
Byte Order DB
(OperatingMode.NotificationMode.DataSource.ByteOrderOfData)
(OperatingMode.ScanMode.DataSource.ByteOrderOfData)
b0:
MSB first
b1:
LSB first
TIMER
(OperatingMode.NotificationMode.DataSelector.Time)
(OperatingMode.ScanMode.DataSelector.Time)
b0:
no internal system timer
b1:
internal system timer will be active
for details).