Identification
Manual
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 140 of 153
H01113-4e-ID-B.docx
Notes:
Additional information about the data table status is transferred if STATUS = 0x00, 0x84,
0x85, 0x93.
9.3. [0x32] Clear Data Buffer
The command Clear Data Buffer clears the data sets from the data buffer which were transferred
with the command.
Host
Reader
1
2
3
4
5
6...7
STX
(0x02)
MSB
ALENGTH
LSB
ALENGTH
COM-ADR
[0x32]
CRC16
Host
Reader
1
2
3
4
5
6
7...8
STX
(0x02)
MSB
ALENGTH
LSB
ALENGTH
COM-ADR
[0x32]
STATUS
22
CRC16
9.4. [0x33] Initialize Buffer
The command Initialize Buffer clears the data buffer to an initial state. It does not matter if the data
sets in the data buffer were read or not.
Host
Reader
1
2
3
4
5
6...7
STX
(0x02)
MSB
ALENGTH
LSB
ALENGTH
COM-ADR
[0x33]
CRC16
Host
Reader
1
2
3
4
5
6
7...8
STX
(0x02)
MSB
ALENGTH
LSB
ALENGTH
COM-ADR
[0x33]
STATUS
1
CRC16
22