Identification
Manual
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 144 of 153
H01113-4e-ID-B.docx
ANNEX E:
Index of Status Bytes
Hex-value
General
0x00
OK:
Data / parameters have been read or stored without error
Control command has been executed
Hex-value
Transponder Status
0x01
No Transponder:
No Transponder is located within the detection range of the Reader.
The Transponder in the detection range has been switched to mute.
The communication between Reader and Transponder has been interfered and the
Reader is not able to read the Transponder anymore.
0x02
Data False:
CRC16 data error at received data.
0x03
Write-Error:
Negative plausibility check of the written data:
Attempt to write on a read-only storing-area.
Too much distance between Transponder and Reader antenna.
Attempt to write in a noise area.
0x04
Address-Error:
The required data are outside of the logical or physical Transponder-address area:
The address is beyond the max. address space of the Transponder.
The address is beyond the configured address space of the Transponder.
0x05
Wrong Transponder-type:
This command is not applicable at the Transponder:
Attempt to write on or read from a Transponder.
A special command is not applicable to the Transponder.