OBID
i-scan
®
UHF
Manual
ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 60 of 193
H90202-7e-ID-B.docx
DB-ADR
1
:
(OperatingMode.BufferedReadMode.DataSource.FirstDataBlock)
(OperatingMode.NotificationMode.DataSource.FirstDataBlock)
(OperatingMode.ScanMode.DataSource.FirstDataBlock)
Address of first data block. Range: 0x00...0xFF.
DB-N
: (OperatingMode.BufferedReadMode.DataSource.NoOfDataBlocks)
(OperatingMode.NotificationMode.DataSource.NoOfDataBlocks)
(OperatingMode.ScanMode.DataSource.NoOfDataBlocks)
Number of data blocks. Range: 0x01...0x20. The data block size in the Buffered Read
Mode is always 2 bytes.
D-START: (OperatingMode.ScanMode.DataSource.FirstByte)
This parameter defines the first byte in the raw data (defined by DB-ADR and D-LGT),
which will be transferred in Scan-Mode. To transfer the whole data block D-START must be
set to 0.
NOTE:
The size of one data block depends on the type of Transponder.
D-LGT:
(OperatingMode.ScanMode.DataSource.NoOfBytes)
D-LGT defines the length of raw data which are transmitted in the Scan-Mode.
Number of
data bytes
to be transferred, starting with the D-START.
Example:
data block
Output Data
0x23
0x45
0x67
0x89
NOTE:
If Wiegand / DataClock is selected as Scan Mode Interface D-LGT indicates the number of
Bits to be transmitted.
8
A plausibility check is performed by writing this parameter to the Reader. If an error occurs the Reader
answers with STATUS = [0x11].
Byte
0
1
2
3
4
5
6
7
Data
0x01
0x23
0x45
0x67
0x89
0xAB
0xCD
0xEF
D-START = 1
D-LGT = 4