OBID
i-scan
®
UHF
Manual
ID ISC.LRU3000/3500
FEIG ELECTRONIC GmbH
Page 102 of 193
H90202-7e-ID-B.docx
7.37. CFG82: Notification Channel, Part 1
Byte
0
1
2
3
4
5
6
Contents
MODE
TIME-
TRIGGERED
-TIME
DATA-SETS-
LIMIT
0x00
KEEP-ALIVE
KEEP-ALIVE-TIME
Default
0x00
0x01
0x00
0x00
0x00
0x02
0x58
continuously
1s
255
Off
600s = 10min
Byte
7
8
9
10
11
12
13
Contents
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Default
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Byte
14
15
16
17
18
19
20
Contents
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Default
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Byte
21
22
23
24
25
26
27
Contents
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Default
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Byte
28
29
Contents
0x00
0x00
Default
0x00
0x00
MODE:
Defines the basic settings for the notification channel.
Bit
7
6
5
4
3
2
1
0
Function
ACK
0
0
0
0
0
DATA-TRIGGER
DATA-TRIGGER: (OperatingMode.NotificationMode.Transmission.NotifyTrigger)
b00:
continuously
b01:
time-triggered
b10:
11.8. [0x34] Force Notify Trigger
The trigger definition is only for data records. In continuous and time-triggered
mode, input / status events, if enabled in