5.4.3 Reducing false Alarms
By creating a blacklist, all transponders placed in the surrounding of the gate will be read and
stored in the blacklist, this will reduce/avoid false alarms.
Step
Action
Note
1
Start ISOStart Software
2
Select
“Configuration”
and
click on
“Read”
to read the
complete configuration.
3
Select
-Operating Mode
Select
“Create Blacklist“
Select
“Sensitivity”
Transponders will never
alarm, also not if they move
through the gate
4
Set by clicking on
„Apply“.
5
The Blacklist will be created
after a “Power On” or
“System Reset” command of
the reader/gate.
Up to 100 Transponder can be stored in the Blacklist.
If more than 100
Transponder are detected an error will be
displayed.
6
Select
“Commands”
7
Select
“ID ISC.ANTU500/270-GA
Commands”
“Reader Diagnostic”
“Read All”
Button
8
Confirm with
„Send“