background image

OBID

® 

classic pro

Installation

ID CPR.02-x

Page 22 of 36 FEIG ELECTRONIC GmbH

1.  Safety instructions – please read carefully prior to initiation

 

The device has to be used only for the purpose designed by the manufacturer.

 

The operation manual has to be stored available at any time and has to be handed over

to each user.

 

Unauthorized changes and the use of spare parts and additional devices which have not

been sold or recommended by the manufacturer may cause fire, electric shocks or

injuries. Such measures will lead to exclusion of any liability by the manufacturer.

 

The liability-prescriptions of the manufacturer in the issue valid at the time of purchase

are valid for the device. The manufacturer is not legally responsible for incorrect,

unsuitable manual or automatical setting of parameters for a device or the incorrect

application of a device.

 

Repairs can only be executed by the manufacturer.

 

Installation-, operation- and maintenance procedures should only be carried out by

qualified personnel.

 

Before opening the device, the power supply must always be interrupted. Make sure

that the device is without voltage by measuring. CAUTION! The fading of an operation

control (LED) is no indicator for an interrupted power supply or the device being

without voltage!

 

Works at the device and its installation have to be executed according to the national

legal requirements and local prescriptions.

 

When working on devices the valid safety regulations must be observed.

 

Caution:
Any modification to the equpment not expressively authorized by the party responsible
for compliance could void the users authority to operate the equipment.

Содержание ID CPR.02-A

Страница 1: ...MONTAGE INSTALLATION preliminary public B 2002 09 13 M10701 1de ID B doc OBID classic pro ID CPR 02 A RS232 Interface ID CPR 02 B RS485 Interface deutsch english...

Страница 2: ...OBID classic pro Montage ID CPR 02 x Seite 2 von 36 FEIG ELECTRONIC GmbH D E U T S C H deutsche Version ab Seite 3 english version from page 20 E N G L I S H...

Страница 3: ...ng f r die Richtigkeit und Vollst ndigkeit der An gaben in diesem Dokument Insbesondere kann FEIG ELECTRONIC GmbH nicht f r Folgesch den auf Grund fehlerhafter oder unvollst ndiger Angaben haftbar gem...

Страница 4: ...und Schalter 10 3 2 Spannungsversorgung 11 3 3 Relais 11 3 4 Digitale Eing nge 11 3 5 RS232 Schnittstelle ID CPR 02 A 11 3 6 RS485 Schnittstelle ID CPR 02 B 12 3 7 Daten Taktschnittstelle 13 4 Inbetr...

Страница 5: ...n f r ein Ger t bzw ungeeignete Verwendung ei nes Ger tes wird keine Haftung bernommen Reparaturen d rfen nur vom Hersteller durchgef hrt werden Anschluss Inbetriebnahme Wartungs und sonstige Arbeiten...

Страница 6: ...hen montiert werden da diese Fl chen eine Redu zierung der Lesereichweite bewirken Der Abstand zu derartigen Fl chen sollte minde stens 3 cm betragen Ist eine Montage auf einer Metalloberfl che notwen...

Страница 7: ...ber in Buchsenleiste X3 einf hren siehe Kapitel Inbetriebnahme 4 Wandmontage Erst nach Kontrolle der Inbetriebnahmearbeiten sollte die Wandmontage erfolgen Geh useoberteil von Unterteil abziehen Geh u...

Страница 8: ...1 gem Abbildung 3 mit den Anschlussklemmen nach unten in das Ge h useunterteil einrasten Dazu die Rasthaken mit den Fingern leicht auseinanderdr cken Geh useoberteil auf Geh useunterteil stecken Dabe...

Страница 9: ...wird Abbildung 4 Anschlussplatine Klemme Funktion Leiste Bezeichnung ID CPR 02 A ID CPR 02 B Spannungsversorgung 12 24 AC DC CLS Daten Taktschnittstelle CLS COM NO Relais GND interner GND R A RS232 R...

Страница 10: ...per und Schalter sind nur bei demontiertem Ger t zug nglich 1 2 3 4 5 6 7 8 ON OFF X7 1 J1 J2 X1 S1 3 2 1 X4 X3 X2 Abbildung 5 Jumper und Schalter S1 DIP Schalter zur Einstellung der Leseradresse X1 S...

Страница 11: ...rden 3 3 Relais Der Leser verf gt ber ein Relais mit einem Schlie erkontakt Der Anschluss erfolgt ber die Klemmen NO und COM 3 4 Digitale Eing nge Die beiden digitalen Eing nge IN1 bzw IN2 d rfen nur...

Страница 12: ...tzt einen Leitrechner mit Abschlusswiderstand und aktiver Terminierung voraus Als Leitung wird eine paarweise verseilte oder verdrillte Leitung empfohlen Host ohne Abschlusswiderstand R A T B ID CPR 0...

Страница 13: ...schnittstelle Der Anschluss der Daten Taktschnittstelle erfolgt gem Abbildung 11 Falls am Host kein CLS Anschluss vorgesehen oder notwendig ist kann auf diese Leitung verzichtet werden Abbildung 11 An...

Страница 14: ...erfolgt mittels der DIP Schalter S1 DIP1 DIP4 ge m Tabelle DIP5 DIP8 haben keine Funktion Dabei wird jeder Leser mit einer indivi duellen Adresse versehen Adresse DIP 1 DIP 2 DIP 3 DIP 4 0 OFF OFF OFF...

Страница 15: ...693 I CODE1 Signalgeber 1 x Bicolor LED rot gr n orange 1 x Summer Relais 1 x Schlie er Kontaktbelastbarkeit 24 V AC DC 1 5 A digitale Eing nge 2 x konfigurierbar Leitungsl nge max 3 m Schnittstellen...

Страница 16: ...on 36 FEIG ELECTRONIC GmbH D E U T S C H 5 1 Zulassung Die Funkanlage entspricht bei bestimmungsgem er Verwendung den grundlegenden Anforde rungen des Artikels 3 und den brigen einschl gigen Bestimmun...

Страница 17: ...OBID classic pro Montage ID CPR 02 x FEIG ELECTRONIC GmbH Seite 17 von 36 5 2 Abmessungen Unterputzmontage Abbildung 12 Abmessungen Unterputzgeh use A Unten...

Страница 18: ...classic pro Montage ID CPR 02 x Seite 18 von 36 FEIG ELECTRONIC GmbH D E U T S C H 5 3 Abmessungen mit ID APR A bei Aufputzmontage Abbildung 13 Abmessungen bei Montage mit Aufputzrahmen ID APR A A Un...

Страница 19: ...mit Leserelektronik 1 x Anschlussplatine 1 x Frontaufkleber 1 x Schneidschraube 3 2 x 25 mm zur Verbindung der Geh useteile 2 x Schneidschrauben 3 2 x 15 mm zur Wandmontage 1 x Montageanleitung 6 1 Op...

Страница 20: ...LEC TRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information Since de...

Страница 21: ...r connection 26 3 1 Jumper and Switches 27 3 2 Power supply 28 3 3 Relay 28 3 4 Digital inputs IN1 IN2 28 3 5 RS232 Interface ID CPR 02 A 28 3 6 RS485 Interface ID CPR 02 B 29 3 7 Data Clock interface...

Страница 22: ...y responsible for incorrect unsuitable manual or automatical setting of parameters for a device or the incorrect application of a device Repairs can only be executed by the manufacturer Installation o...

Страница 23: ...faces metal grids reinforcements or metallized surfaces as these surfaces reduce the detection range of the Reader The distance between the Reader and such surfaces should be min 3 cm If an installati...

Страница 24: ...has to be inserted carefully into the socket board X3 see chapter Installation 4 Wall installation The wall installation should be executed only after a control of all functions Remove top of the cas...

Страница 25: ...lose casing Snap in connection board 1 to bottom part of casing according to Fig 3 with the connectors in downward direction In order to do this press the notches slightly apart with your fingers Put...

Страница 26: ...rt of the casing Fig 4 Connection board connector function board name ID CPR 02 A ID CPR 02 B power supply 12 24 AC DC CLS data clock interface cls COM NO relay GND internal GND R A RS232 RxD RS485 A...

Страница 27: ...02 x The jumpers and switches are only accessible at the opened device 1 2 3 4 5 6 7 8 ON OFF X7 1 J1 J2 X1 S1 3 2 1 X4 X3 X2 Fig 5 Jumper and Switches S1 DIP switch to configure the Reader address X...

Страница 28: ...voltage wires 3 3 Relay The device is equipped with an relay normally open contact The connection is executed via the connectors NO and COM 3 4 Digital inputs IN1 IN2 The digital inputs IN1 and IN2 ca...

Страница 29: ...ig 5 To operate the bus you need a host computer with a terminating resistor and active termination A twisted paired or stranded wire is recommended Host without termination R A T B ID CPR 02 A with a...

Страница 30: ...GmbH 3 7 Data Clock interface The connection of the data clock interface is executed according to Fig 11 If no CLS signal is required on host this connection can be abandon Fig 11 connection of the d...

Страница 31: ...a the DIP switches S1 DIP1 DIP 4 according to the table seen below DIP5 DIP8 are unused Thus each Reader is being provided with an individual address Address DIP 1 DIP 2 DIP 3 DIP 4 0 OFF OFF OFF OFF...

Страница 32: ...SO15693 I CODE1 signal transmitter 1 x bicolor LED red green orange 1 x buzzer relay 1 x normally open capacity of contacts 24 V AC DC 1 5 A digital inputs 2 x configurable length of lead in wire max...

Страница 33: ...n ID CPR 02 x FEIG ELECTRONIC GmbH Page 33 of 36 5 1 Approval When properly used this radio equipment conforms to the basic requirements of Article 3 and the other relevant provisions of the R TTE Dir...

Страница 34: ...OBID classic pro Installation ID CPR 02 x Page 34 of 36 FEIG ELECTRONIC GmbH 5 2 Dimensions for concealed installation Fig 12 Dimensions of concealed casing A below...

Страница 35: ...BID classic pro Installation ID CPR 02 x FEIG ELECTRONIC GmbH Page 35 of 36 5 3 Dimensions for surface installation with ID APR A Fig 13 Dimensions for installation with surface frame ID APR A A below...

Страница 36: ...Reader electronic 1 x connection board 1 x adhesive label 1 x thread cutting screw 3 2 x 25 mm for connecting parts of casing 2 x thread cutting screws 3 2 x 15 mm for wall installation 1 x Installati...