IDENTIFICATION 

ID MAX.U500i 

2  Performance Features 

 

 

 

Page 6 of 36 

 

 

2  Performance Features of ID MAX.U500i 

Performance Features 

 

2.1  Performance Features 

 

With its compact size, its weather-resistant housing, a read range of 8 to 10 m and the circular-polarized 
antenna supporting any transponder orientation, the UHF Vehicle Access Control Reader ID MAX.U500i is 
ideally suited to provide efficient and secure vehicle access control. Up to 9000 users and vehicles can be 
stored in the internal storage of the ID MAX.U500i. 
The vehicle access control reader can be easily installed on a VESA mount next to a barrier, gate or bollard 
due to its mechanical construction. To install the compact reader one cable is required for each interface and 
power supply; for PoE only the network cable is required. 

 
2.2  myAXXESS Manager 

 

With the help of the software myAXXESS Manager user data and access rights can be easily handled via 
PC. After programming the access rights into the vehicle access control reader via a temporary USB or 
network connection the reader is working offline as a standalone system. 
The Windows software is suitable for network based vehicle and door access control systems and is based 
on a SQL database. The myAXXESS Manager is available in the FEIG download area. 
In small applications without any time restrictions for the access rights new transponders can be added to 
the reader by the Teach-In Mode without above mentioned software (See chapter 6.2.1 Teach-In Mode on 
page 24.). 

 

2.3  Available Reader Types 

 

The following readers are available: 

Order Number  Reader Type 

Description 

5118.001.00 

ID MAX.U500i-EU 

Device version for Europe 

5118.001.10 

ID MAX.U500i-FCC 

Device version for North America 

 

 

 

 

Содержание 5118.001.00

Страница 1: ...IDENTIFICATION M81211 2e ID B INSTALLATION ID MAX U500i EU 5118 001 00 FCC 5118 001 10...

Страница 2: ...t be completely avoided we are always grateful for your useful tips The instructions given in this manual are based on advantageous boundary conditions FEIG ELECTRONIC GmbH does not give any guarantee...

Страница 3: ...via PoE Power over Ethernet 15 5 3 Ethernet Interface on Connector X1 16 5 4 Digital Outputs on Connector X4 17 5 5 Relay Outputs on Connector X4 18 5 6 Digital Inputs on Connector X5 19 5 7 USB Mini...

Страница 4: ...e Transponder 28 9 Technical Data 29 10 Radio Approvals 31 10 1 Europe CE 31 10 2 USA FCC and Canada IC 32 10 2 1 USA FCC and Canada IC Warning Notices 32 10 2 2 Installation with FCC IC Approval 32 1...

Страница 5: ...inaccuracies errors or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device Repairs may only be executed by the manufacturer Installation o...

Страница 6: ...PoE only the network cable is required 2 2 myAXXESS Manager With the help of the software myAXXESS Manager user data and access rights can be easily handled via PC After programming the access rights...

Страница 7: ...ng insert for 1 cable cable 4 6 5 mm 1 x ESKV 20 M20 cable gland for cable 6 13 mm for USB 1 x RDE 20 M20 reduction sealing insert for cable 4 8 mm 1 x MFD 20 02 040 M20 multiple sealing insert for 2...

Страница 8: ...screws used should have a screw in depth of maximum 8 mm The housing can be opened by means of a hinge Therefore loosen the screws marked blue in Fig 1 and swing away the front part of the reader Duri...

Страница 9: ...IDENTIFICATION ID MAX U500i 4 Installation Page 9 of 36 Fig 2 Dimensional drawing side view...

Страница 10: ...IDENTIFICATION ID MAX U500i 4 Installation Page 10 of 36 Fig 3 Dimensional drawing top view opened housing...

Страница 11: ...ION ID MAX U500i 4 Installation Page 11 of 36 NOTE FEIG ELECTRONIC GmbH strongly recommends to secure the reader against falling by means of an eye bolt to prevent damage Fig 4 Secondary protection vi...

Страница 12: ...s Table 2 lists the available operating and display elements Fig 5 Connection Overview Connector Description X1 10 100 Base T Ethernet with RJ45 X2 Power Supply 12 24 V DC 1 0 X4 Relay Outputs Digital...

Страница 13: ...The TNC socket for connecting the external antenna is located on the lower side of the reader The maximum tightening torque for the TNC sockets is 0 69 Nm 6 11 lbf in Fig 6 External antenna connection...

Страница 14: ...upply according EN 62368 1 Chapter Q 1 or with a NEC Class 2 LPS certified power supply Each reader has to be supplied by a separate external power supply Reversing the polarity of the supply voltage...

Страница 15: ...nces can be used Conductor Cross Section CAT5 7 Max Cable Length for PoE 0 4 mm 30 m 0 6 mm 70 m Table 5 Max cable length depending on the conductor cross section For detailed technical information re...

Страница 16: ...d be used This ensures a reliable operation at 10 Mbps or 100 Mbps The prerequisite for using TCP IP protocol is that each device has a unique IP address on the network All readers have a factory set...

Страница 17: ...itry The output must therefore be supplied with an external voltage Each output is linked fixed with an antenna Reading of a valid transponder on the internal antenna will affect the digital output OP...

Страница 18: ...nnector X4 There are 2 relay outputs available at terminal X4 as normally open contacts Each output is linked fixed with an antenna Reading of a valid transponder on the internal antenna will affect t...

Страница 19: ...ntacts must be protected by an external protective circuit 5 6 Digital Inputs on Connector X5 There are 2 digital inputs available on X5 The optocouplers on X5 are galvanically isolated from the reade...

Страница 20: ...istor Rext is optional When wiring the reader make sure that the input voltage is at least 10 5 V CAUTION The inputs are designed for an input voltage of 12 24 V DC and an input current of max 20 mA P...

Страница 21: ...ptionally available USB On The Go adapter cable the interface can be converted to a USB host interface The adapter cable allows the connection of a USB memory stick to the reader The USB memory stick...

Страница 22: ...lash drive This file will be stored in the root directory of the USB flash drive for easy copying of the configuration See chapter 5 7 4 Copying the Configuration onto a Reader Config Cloning on page...

Страница 23: ...n the reader If configuration pages are password protected the configuration file will not be copied onto the reader This also applies if individual configuration parameters contain values out of the...

Страница 24: ...ce error unequal 50 Table 11 Antenna status LED overview 6 2 Push Button T1 By means of the push button T1 a complete configur ati on reset can be performed The push button is l ocated between the DIP...

Страница 25: ...urer or other system provider These transponders could also be detected by the reader in Teach In Mode 6 2 2 Configuration Reset By means of the push button T1 a complete configuration reset can be pe...

Страница 26: ...vehicle type The antenna should be mounted at an angle of approx 45 to the roadway If the vehicle access control reader is used to control a barrier the antenna should be mounted at a sufficient dista...

Страница 27: ...IDENTIFICATION ID MAX U500i 7 Positioning of the Antenna Page 27 of 36 Fig 19 Typical vehicle access control application Fig 20 Positioning of the antenna...

Страница 28: ...be thoroughly cleaned to ensure optimum adhesion of the self adhesive labels Vehicles with integrated windshield heating require special mounting of the transponder In this case the transponder shoul...

Страница 29: ...trol Internal Overheating Protection Outputs 2 x Optocoupler 2 x Relay max 24 V DC 20 mA max 24 V DC 1 A switching current 2 A permanent current Inputs 2 x Optocoupler max 24 V DC 20 mA CAUTION Overhe...

Страница 30: ...85 C Humidity 5 to 95 non condensing Vibration EN 60068 2 6 10 Hz to 150 Hz 0 075 mm 1 g Shock EN 60068 2 27 Acceleration 30 g APPLICABLE STANDARDS Radio Regulation Europe USA Canada India EN 302 208...

Страница 31: ...C GmbH declares that the radio equipment type ID MAX U500i is in compliance with Directive 2014 53 EU The full text of the EU declaration of conformity is available at the following internet address h...

Страница 32: ...ll be required to correct the interference at his own expense L metteur r cepteur exempt de licence contenu dans le pr sent appareil est conforme aux CNR d Innovation Sciences et D veloppement conomiq...

Страница 33: ...e I a t approuv par Industrie Canada pour fonctionner avec les types d antenne nonc ci dessus et ayant un gain admissible maximal et l imp dance requise pour chaque type d antenne Les types d antenne...

Страница 34: ...m 5243 002 00 ID ANT C6 C UHF Antenna Cable R TNC TNC 6 m H155 Coaxial cable for UHF antennas with TNC socket and UHF reader with R TNC connector Connection type Connector R TNC Connector TNC Length 6...

Страница 35: ...ring of the power supply 14 Table 5 Max cable length depending on the conductor cross section 15 Table 6 Standard factory configuration of the Ethernet connection 16 Table 7 Pin Assignment X4 Digital...

Страница 36: ...nector 16 Fig 10 Connector X4 pin assignment for digital outputs 17 Fig 11 internal and external wiring of the digital outputs 17 Fig 12 Connector X4 pin assignment for relay outputs 18 Fig 13 Externa...

Отзывы: