IDENTIFICATION
ID LRU500i
5 Terminals
Installation
Page 16 of 35
5.3 Ethernet Interface on Connector X1
The reader has an integrated 10/100 base-T network port for an RJ-45. Connection is made on X1 and has
an automatic “Crossover Detection” according to the 100BASE-T Standard.
With structured cabling STP CAT5 cables should be used. This ensures a reliable operation at 10 Mbps or
100 Mbps. The prerequisite for using TCP/IP protocol is that each device has a unique IP address on the
network. All readers have a factory set IP address. The transmission parameters can be configured as
required.
Network
Address
IP Address
192.168.10.10
Subnet Mask
255.255.0.0
Port
10001
DHCP
OFF
Table 6: Standard factory configuration of the Ethernet connection
NOTE
The reader is equipped with a DHCP ready Ethernet interface.
Fig. 9: Ethernet connector