24
WARNING
Contact with a hot engine or exhaust system can cause serious bums or fires. Let the
engine cool before transporting or storing the generator.
Take care not to drop or strike the generator when transporting. Do not place heavy objects on the
generator.
Before storing the unit for an extended period:
• Be sure the storage area is free of excessive humidity and dust.
• Service according to the table below:
STORAGE TIME
RECOMMENDED SERVICE PROCEDURE TO PREVENT HARD
STARTING
Less than 1 month
No preparation required.
1 to 2 months
Fill with fresh gasoline and add gasoline conditioner*
2 months to 1 year
Fill with fresh gasoline and add gasoline conditioner*
Drain the carburetor float bowl.
Drain the fuel sediment cup.
1 year or more
Fill with fresh gasoline and add gasoline conditioner*
Drain the carburetor float bowl.
Drain the fuel sediment cup.
Remove the spark plug. Put a tablespoon of engine oil into the cylinder.
Turn the engine slowly with the pull rope to distribute the oil.
Reinstall the spark plug.
Change the engine oil.
After removal from storage, drain the stored gasoline into a suitable
container, and fill with fresh gasoline before starting.
*Use gasoline conditioners that are formulated to extend storage life.
Contact your authorized generator dealer for conditioner recommendations.
1) Drain the carburetor by loosening the drain screw. Drain the gasoline into a suitable container.
WARNING
Gasoline is extremely flammable and is explosive under certain conditions. Perform this
task in a well ventilated area with the engine stopped. Do not smoke or allow flames or
sparks in the area during this procedure.