Start the Generator

1.

Start the generator in the following way(s).

a.Recoil start:

i. Turn the fuel switch to start.

ii. Pull outward the choke cable.

iii. Gently pull the handle until you feel resistance

then quickly pull the handle to start the

generator.

iv. According to the ambient temperature, push the choke cable inward after the starting the

generator. The lower the ambient temperature is, the slower the inward pushing is. The higher
the ambient temperature is, the faster the inward pushing speed is. Make sure the engine does
not turn off when pushing inwards.

2. When the output indicator on the control panel is ON, the generator is ready to use. The generator should be

grounded before connecting to any load. Please use cable to connect the ground terminal on the generator
control panel to an external ground source.

3. Please make sure the connected equipment is in good condition and turned off. Also make sure that the total

power of the appliance used does not exceed the max. power of the generator.

4. Connect your equipment to the appropriate output socket on the generator control panel.

Turn off the Generator

NOTICE

Turn the ignition key to “OFF” position, the generator will stop immediately in any condition.

Turn off the generator in the following instructions:
1. Turn off and unplug the connected equipment.
2. Turn the ignition key to “OFF” position to stop the generator. Or press the “STOP” button on the remote

controller or the red “STOP” button on the control panel to stop the generator for Remoter Start model.

3. Turn off the fuel switch.

When not using the generator for a long time, please turn off the generator.

Forewords

Thank you for Choosing our generator.
This manual includes the operation and maintenance of Model

FG1600I-A

series inverter generator. All contents of

this manual are consistent with the latest products (when this manual is printed).
Our company reserves the right to make changes without notice and without any liability.
This manual is owned by

BUILIDER SAS

and is not allowed to be recorded without written permission. This manual

should be considered as a permanent part of the generator and should be kept with it if the generator is resold.

Pay special attention to statements preceded by the following words

08

Содержание FG1600i-A

Страница 1: ...GENERATOR LOW GENERATING SET ORIGINAL INSTRUCTION MANUAL MODEL FG1600i A BUILDER SAS ZI 32 rue Aristide Berg s 31270 Cugnaux France Made in P R C 2021 Warning read the following instructions before us...

Страница 2: ...ng area The operator or the user are responsible for possible accidents or damage to other persons or to their property Do not wear loose clothing or jewellery as this can get caught in the machinery...

Страница 3: ...anical constraints it is necessary to use a flexible sheathed cable with a strong rubber protective layer conforming to IEC 245 4 or a similar cable If using an electrical extension cable the total le...

Страница 4: ...othing wash or change your clothes Always stop the motor of the generator when filling it with fuel Never fill the fuel tank while smoking or near a naked flame Make sure you don t spill fuel on the m...

Страница 5: ...erate fires in the building s electrical installation Before connecting electrical devices to the generator make sure that their voltage specifications and frequency of functioning correspond to the t...

Страница 6: ...or in an enclosed room because exhaust emissions can lead humans or animals to coma to death This symbol indicates the surface is very hot and not touching Keep away from the machine Exhaust emissions...

Страница 7: ...unscrew the dipstick to check the oil level If oil level is below the bottom of the dipstick add recommended oil capacity 0 4L Use a strong detergency four stroke engine oil and choose proper viscosi...

Страница 8: ...ipment to the appropriate output socket on the generator control panel Turn off the Generator NOTICE Turn the ignition key to OFF position the generator will stop immediately in any condition Turn off...

Страница 9: ...ructions in this manual the generators are safe and reliable Be sure to read and understand the instructions before use otherwise the wrong operation will result in personal injury or equipment damage...

Страница 10: ...Parts Identification The configurations of control panel might be different Fuel Cap Control Panel Fuel tank Handle Feet Exhaust port 10...

Страница 11: ...detergency high quality 4 stroke engine oil which must meet or exceed US automobile manufacturer s requirements of the American Petroleum Institute classification SG SF levels Choose the appropriate...

Страница 12: ...oil level If the oil level is below the bottom of the dipstick add the recommended oil BE CAUTIOUS Operation of the engine with insufficient engine oil may cause serious damage to the engine The oil...

Страница 13: ...ary clean or replace the filter sponge d Clean or replace the filter and then follow the opposite action to install the air filter WARNING Under certain conditions gasoline is extremely flammable and...

Страница 14: ...he engine through the carburetor and cause rapid wear of the engine Start the Engine Recoil Start Disconnect the load from the socket before starting the generator 1 Turn the oil switch to ON position...

Страница 15: ...erature of the engine When you add the fuel the first time or refuel the generator the fuel is not stored in the carburetor The start handle should be pulled 3 5 times and then adjust the throttle arm...

Страница 16: ...main jet on the carburetor smaller while adjusting the ratio mixing screw then you can change the performance of the engine in high altitude areas If you are always using the generator at an altitude...

Страница 17: ...UTIOUS When the generator is running continuously do not exceed the rated power In other cases pay attention to the total power of the connected equipment Do not exceed the rated current of the socket...

Страница 18: ...the connected device BE CAUTIOUS If the connected device is not turned off before you start the generator it will start suddenly resulting in personal injury If the generator is overloading or the con...

Страница 19: ...confirm that the problem has been resolved press the Reset Button on the control panel After 3 seconds the indicator will turn green and the generator will start operating normally If you press the Re...

Страница 20: ...0 90 500 0 93 0 88 0 83 0 78 0 73 1000 0 87 0 82 0 77 0 72 0 67 2000 0 75 0 70 0 65 0 60 0 55 3000 0 64 0 59 0 54 0 49 0 44 4000 0 54 0 49 0 44 0 39 0 34 Note When the relative humidity is 60 the amb...

Страница 21: ...might damage the generator Charging cable should be properly connected to the positive and negative terminals of the battery otherwise it will damage the generator or the battery WARNING Charge should...

Страница 22: ...ns in the on position After the engine alarm system shuts down the engine if the user tries to start the engine again the oil alarm indicator red will flash briefly and the engine will no longer opera...

Страница 23: ...2 Turn the switch to STOP position 3 Turn the oil switch to OFF position When not using the generator for a long time please turn off the generator Turn off Switch 23...

Страница 24: ...Adjustment 3 Fuel tank and filter Clean 3 Fuel line Examination Every 2 years if necessary please change 3 Note 1 Normal maintenance interval 2 In areas where pollution is severe check and repair fre...

Страница 25: ...the oil alarm system works properly Oil capacity 0 4L Wash your hands with soap and water after you touch the oil BE CAUTIOUS In order to comply with environmental requirements we recommend that coll...

Страница 26: ...over screws open the side maintenance cover b Remove the three screws on the air filter box c Pull out the air filter drawer as shown by the arrow below d Pull out the air filter drawer check the air...

Страница 27: ...Ignition coil Spark plug removal tool 27...

Страница 28: ...spark plug with different heat value Maintenance of Muffler Fireproof Net Dirty muffler will affect the muffler effect of the generator and the power of the engine To ensure the normal operation of t...

Страница 29: ...f the generator is placed in a sealed compartment the high temperature inside the compartment may cause the fuel to evaporate and cause an explosion Do not transport the generator on a rough road for...

Страница 30: ...rt please follow the troubleshooting instruction above NOTICE Make sure no fuel spills around the spark plug Spilled fuel may catch fire Check spark plug 1 Remove the anode cap and clean the dirt arou...

Страница 31: ...ce work Shut off the generator and wait until the overload indicator turns off then start again or press the reset button to restart the generator 1 Replace the device 2 Get the device repaired Is DC...

Страница 32: ...y 0 4 L Fuel Tank Capacity 4 5 L Spark Plug E7RTC Noise Level 7m 59dB A Measured noise pression level LPA 72 26dB A K 0 92dB A Measured noise power level LwA 92 26dB A K 0 92dB A Guaranteed noise powe...

Страница 33: ...2016 EN 55012 2007 A1 2009 EN 61000 6 1 2007 Measured sound power level LwA 92 26dB A k 0 92dB A Guaranteed Sound power level 95 dB A Philippe MARIE PDG Is in confirmity with the essential requirement...

Страница 34: ...he user manual Due to our policy of continuous product improvement we reserve the right to alter or change specifications without notice Consequently the product may be different from the information...

Страница 35: ...before dropping off the machine Go to the repair station with the complete machine packed accompanied by the purchase invoice and the station support sheet downloadable after the service request is co...

Страница 36: ...essary for repairs and more generally the costs related to the immobilization of the product The costs of a second opinion established by a third party following an estimate by a SWAP Europe repair st...

Отзывы: