INTERIOR
EXTERIOR
36"
2-3/4" MIN. LAG PENETRATION
6" LAG SCREWS,
PART #7278
42"
RESIDENTIAL (MAX 6' OC)
38"-42"
COMMERCIAL (MAX 4' OC)
3-5/8" MIN. LAG PENETRATION
6-1/2" LAG SCREWS,
PART #7209
3" MIN. LAG PENETRATION
6" LAG SCREWS,
PART #7278
4" MIN. LAG PENETRATION
7" LAG SCREWS,
PART #7248
VINYL CAP
3/8" Ø LAG SCREW
(REFER TO CHART
FOR LENGTH
REQUIREMENTS)
T H I S D RA W I N G I S T H E P R O P E R T Y O F F E E N E Y I NC . A N Y R E P RO DU CT I ON O F T H I S D OC UM E NT W I T HO U T T HE E X P R E S S E D W RI T T E N CO NS E N T O F F E E NE Y I N C. I S S T R I C T L Y P R O HI B I T E D .
DATE:
PAGE:
REV:
BY:
CHK:
2603 Union St., Oakland, CA 94607
P: 800-888-2418 F: 510-788-6041
www.feeneyinc.com
DesignRail
®
Detail Drawing:
Fasica Mount with Lag Screws
06/10/15
1 OF 1
BWA
NOTES:
MINIMUM LAG PENETRATION DIMENSION, REFER TO REQUIREMENTS FOR
LAG SCREW PENETRATION INTO SOLID LUMBER. LUMBER ASSUMED TO
HAVE A MINIMUM 0.43 SPECIFIC GRAVITY (ie: HEM-FIR).
RIM JOIST AND BLOCKING MUST BE PROPERLY ATTACHED TO STRUCTURE
TO RESIST TRANSFERRED LOADS FROM POSTS.
IF USING COMPOSITE MATERIAL AS FASCIA BOARD, FASCIA THICKNESS
WILL NOT CONTRIBUTE TO PENETRATION REQUIREMENT. LAG SCREW
LENGTH AND BLOCKING MUST BE ADJUSTED TO ACCOUNT FOR
ADDITIONAL LENGTH, AS NECESSARY.
BOLT PATTERN MAY VARY DEPENDING ON JOIST HEIGHT AND PROJECT
TYPE.
3" MIN. LAG PENETRATION
6" LAG SCREWS,
PART #7278
4" MIN. LAG PENETRATION
7" LAG SCREWS,
PART #7248
RIM JOIST WITH
REQUIRED
BLOCKING
CAP WASHER,