background image

FeelTech

6

SGP3000 Series Users Manual

1

Press

MENU

button under sweep function interface to enter beginning frequency setting

interface.

F=00021.00000kHz
SWEEP BEGIN FREQ

Use

】、【

】、【

to change beginning frequency value.

Use

OK

to save current beginning frequency value.

2

Press

MENU

button under beginning frequency setting interface to enter end frequency

setting interface.

F=00021.00000kHz
SWEEP END FREQ

Use

】、【

】、【

to change end frequency value.

Use

OK

to save current end frequency value.

3

Press

MENU

button under end frequency setting interface to enter sweep time setting

interface.

F=00021.00000kHz
*FUNC:TIME=001S

Use

】、【

】、【

to set sweep time.

Use

OK

to save current sweep time value.

Note: The step value of frequency sweep is affected by sweep time. It is updated every 10 ms.
The step value is calculated by the instrument itself.

9

Load/Save function

Press

SYS

button to enter Save/Load function. This function allow the user to save to or load

from M0~M30 for frequency, amplitude, offset, duty cycle, waveform, phase and so on.

Press

】、【

to select from M0~M30. Then press

OK

button. The screen will

display “OK” and the parameters have been loaded successfully.

F=00021.00000kHz

*FUNC:LOAD=00 OK

If it displays

Non”, it means no data saved at this position

F=00021.00000kHz

*FUNC:LOAD=00 Non

1

Press

SYS

button under loading interface to enter saving interface. The current frequency,

amplitude, offset, duty cycle, waveform and phase can be saved. This instrument has 31
positions for saving.

Press

】、【

to select the position for saving

M0~M30

)。

Press

OK

button,

the screen display “M” and saving completed.

Parameters of M0 are the default parameters at start-up.

F=00021.00000kHz

*SAVE P_ON FREQ

Position M1~M30 is planed by user. Interface as follows:

Содержание FY2300 series

Страница 1: ...FeelTech FY2300 Series Fully Numerical Control DDS Signal Generator User s Manual Rev2 0 Feb 2016...

Страница 2: ......

Страница 3: ...n in this publication replaces all previously corresponding material FeelTech shall not be liable for losses caused by either incidental or consequential in connection with the furnishing use or perfo...

Страница 4: ......

Страница 5: ...interference immunity and operational life span The advantages of this instrument in signal generating waveform sweeping parameter measurement and other fields make it to be the ideal equipment for e...

Страница 6: ...n can output any CMOS electric level with amplitude during 0 10V Save Function It can save 30 sets of user defined parameters and can be loaded at anytime It has built in 60MHz frequency meter and cou...

Страница 7: ...the cursor twinkles under the frequency value If not please keep pressing MENU button to move the cursor to the first line Use button to change the value of frequency for increasing for decreasing F...

Страница 8: ...to change the value F 00021 00000kHz AMPL 05 00V TRGL 4 To set the offset Press OFFS button to make the cursor stay under the offset value OFS Then use to change the offset value F 00021 00000kHz OFS...

Страница 9: ...witch between frequency meter and counter 1 Frequency measurement mode ExtF 21 000kHz FUNC EXT TREQ Measure FREQ 2 Pulse counter mode CNTR 0 FUNC COUNGTER Measure COUNT Press OK button canreset the co...

Страница 10: ...10 ms The step value is calculated by the instrument itself 9 Load Save function Press SYS button to enter Save Load function This function allow the user to save to or load from M0 M30 for frequency...

Страница 11: ...w Press Output again to turn on the output F 00021 00000kHz AMPL 05 00V OFF Other Functions 1 Dual Channel TTL output 2 Buzzer It beeps each time press a button The beep will last a while if operation...

Страница 12: ...5MHz Ramp Triangle 0 2MHz 0 5MHz 0 5MHz 0 5MHz Pulse 0 2MHz 0 5MHz 0 5MHz 0 5MHz TTL 0 2MHz 0 5MHz 0 5MHz 0 5MHz Others 0 2MHz 0 5MHz 0 5MHz 0 5MHz Resolution 10mHz 0 01Hz Accuracy 5 10 6 Stability 1...

Страница 13: ...n 0 01V 0 001V Attenuated TTL output Electrical Level Amplitude 5Vpp Fan out 20 TTL Load Rise Fall Time 20ns CMOS output Low Electric Level 0 3V High Electric Level 1V 10V Rise Fall Time 20ns External...

Страница 14: ...erial interface Communicati ng Speed 9600bps Protocol Command line mode protocol complete open Power Voltage Range DC12V Buzzer Can be turned on off by setting Operation Button controlled Environment...

Страница 15: ...pecial purpose or use authorization Before the installation and use each parameter of the technical indexes in this manual should be referred to If this suggestion is not obeyed death or serious perso...

Страница 16: ...duct is proven to be defective within the respective period FeelTech guarantees the free replacement or repair of products which are approved defective This product enjoy 1 year warranty since its del...

Отзывы: