Feellife Air Smart T1 Скачать руководство пользователя страница 16

15

Figure 13 Settings interface

1) Language
Select "Language" in Settings interface, then press UP or DOWN key to select

"English" or "Chinese" (If this device does not have built-in language selection

function, the operation is invalid).
2) Bluetooth
Select "Language" in Settings interface, then press UP or DOWN key to select

"ON"/"OFF".Collect your phone and this device via Bluetooth.You can review the

data by this way.
How to use the Bluetooth?
Step 1:Install the APP according to scan the QR code.

Step 2:Open the Bluetooth on your phone.Open the APP and the interface are shown

as below.

Step 3:Click “Device”, and it will connect automatically.
Step 4:Click “Lung”,you can view your test result.
Step 5:Click “Experience” and the interface are shown as below.You can know more

about our product by entering “Medical” and “Productions” module.

Содержание Air Smart T1

Страница 1: ...1 User Manual for SPIROMETER Model Air Smart T1 Doc LFS EN UM 24D Issue date Apr 2 2021 Rev V1 0...

Страница 2: ...tions 8 7 Cleaning and Disinfection 18 8 Storage and Maintenance 19 9 Contraindications Precautions and suggestive contents 19 10 Trouble Shooting 21 11 Note Warning 22 12 After sales Service 23 13 Sy...

Страница 3: ...ct use of this product please read this instruction for use carefully before using Please keep this instruction for use in a place where convenient for reading at any time The illustrations in this in...

Страница 4: ...C FEV1 FEV1 FVC PEF etc The spirometer is intended to be used by a physician or by a patient under the instruction of a physician or paramedic 2 Working Principle Inhale deeply seal your lips around y...

Страница 5: ...r Model Air Smart T1 Internal power supply DC 3 7 V 2000mAh rechargeable lithium battery External power supply With DC 5 V 1 A adapter Display mode LCD display Flow range 16 l s deviation 10 or 0 3 l...

Страница 6: ...smission has communication protocol requirements 4 0 4 Service life The main unit 5 years Turbine 1 year 5 Shelf life Disposable mouthpiece 3years Turbine 3years 5 Installation Guideline 5 1 Turbine a...

Страница 7: ...7 Caution 1 The disposable mouthpiece is a paper material it is designed for single user and single use It is not allowed for multi users...

Страница 8: ...of 30 mm is of common use and in general easily procured 5 4 Power supply preparation 1 This device uses 3 7 V rechargeable lithium battery It is not equipped with a power adapter Please use an adapte...

Страница 9: ...on If you need to replace the battery please consult the manufacturer 6 Operating Instructions 6 1 ON OFF key After assembly long press about 3 seconds the ON OFF key to turn on off the device 6 2 Mea...

Страница 10: ...full chest and abdominal expansion to avoidexternal restrictions on lung function 1 After turning on the device it will locate in selective interface shown as Figure 1 press UP or DOWN key to select Y...

Страница 11: ...to the predicted value vividly The comparison of measured value with the reference value in same situation It is red when the value is lower than 50 which means that the user should pay attention to...

Страница 12: ...ey to select corresponding item then press CONFIRM key to enter its sub menu methods are as followings Figure 5 Menu interface Personal information Under Menu interface select Personal information to...

Страница 13: ...is 6 101 Adjustable range of Height is 80 241 cm Adjustable range of Weight is 15 250 Kg The equation of predicted value can be set in Equation item including ECSC KNUDSON and USA 3 Exit In Personal...

Страница 14: ...d change vividly which is convenient for user to compare If there are too much data press UP or DOWN key in the curve to browse all data trend in turn Press CONFIRM key to return to Data Management in...

Страница 15: ...t interface The Health status indicator will show in accordance with the parameter you set as shown to Figure 3 Figure 12 Denote value setting interface 5 Exit In Data Management interface select Exit...

Страница 16: ...elect ON OFF Collect your phone and this device via Bluetooth You can review the data by this way How to use the Bluetooth Step 1 Install the APP according to scan the QR code Step 2 Open the Bluetoot...

Страница 17: ...r Figure 14 Time setting interface 4 About You can select About in Settings interface to enter its sub menu and check the device name and software version then press CONFIRM or RETURN key you can retu...

Страница 18: ...be searched and connected with other devices When the connection is built successfully the device displays data transmission icon Caution 1 This device will automatic power off when there is no operat...

Страница 19: ...18 FEF75 Forced expired flow at 75 of FVC l s FEF2575 Forced expiratory flow between 25 and 75 of l s...

Страница 20: ...f the main unit After cleaning let it air dry Do not put the device into water or other fluids Caution 1 The main unit cannot be cleaned or soaked in clean water so as to prevent water from entering i...

Страница 21: ...ot twist the USB cable 5 If you have any trouble during using process please seek solutions according to Trouble Shooting section If this device still cannot work normally please contact the manufactu...

Страница 22: ...Note Spirometry should be discontinued if the patient experiences pain during the maneuver Patients with potential contraindications that would prevent testing in the primary care setting may be test...

Страница 23: ...g time and the data can t be displayed The start speed is too low the device does not measure Remeasure according to the Operational Guideline section Device malfunction Please contact the manufacture...

Страница 24: ...er to Cleaning and Disinfection section Please keep the accessories dry when store them Please assure all the accessories assembled rightly before using Don t use this device under inflammable gas env...

Страница 25: ...ctrical or electromagnetic fields near the medical device Waste disposal discard the main engine and accessories according to local laws and regulations The USB cable should be kept away from children...

Страница 26: ...ildren or pets to prevent animal hair or dirt entering the turbine to affect its use 12 After sales Service 1 After this device is packed under the condition of following the storage and use regulatio...

Страница 27: ...gulations Electromagnetic compatibility 13 1 Symbol description General symbol Description title General symbol Description title Date of manufacture General warning sign Manufacturer information Refe...

Страница 28: ...application part for protection of defibrillation discharge effect no application part for defibrillation prevention 8 Whether there is signal output or signal input part there is signal input or sign...

Страница 29: ...ice should assure that they are used in such an environment Immunity test IEC 60601 test level Compliance Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 8kV contact 2kV...

Страница 30: ...st IEC 60601 test level Compliance level Electromagnetic environment guidance 6Vrms in ISM and amateur radio bands 6Vrms in ISM and amateur radio bands Portable and mobile RF communicationsequipment s...

Страница 31: ...red field strength in the location in which the device is used exceeds the applicable RF compliance level above the device should be observed to verify normal operation If abnormal performance is obse...

Страница 32: ...E 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people 14 Configuration List Item Quantity If Incl...

Страница 33: ...Any repair service out of the scope of warranty will be charged accordingly 16 Manufacturer and Rep information FEELLIFE HEALTH INC Room 1903 Building A No 9 Furong Road Tantou Community Songgang Subd...

Страница 34: ...s and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that int...

Отзывы: