FeelElec FY8300S Series Скачать руководство пользователя страница 10

FeelElec

 

8

                                                                                  FY8300S Series User

s Manual

 

    Can sweep Sine, Square, Arbitrary and so on.   

    Can sweep frequency, amplitude, offset and phase. 

  2 sweep types: Linear, Logarithm. 

  VCO  voltage  controls  parameters  of  signal  output 

available (for example: voltage controlled oscillator). 

    Auxiliary functions and system configuration setting. 

    Can  save  12  sets  waveform  parameters  including 

frequency, amplitude, offset, phase and so on. 

    System  Language  has  English  and  Chinese  for 

user

s option. 

    Buzzer can be turned on/off in this manu. 

    Set multimachine uplink. 

  Switch Master-Slave status 

                         

    Set default status of three channels at start-up. 

    Trigger and modulation function button 

    Set definite amount of pulse string to output. 

    Set modulation mode: ASK, FSK, PSK 

    VCO function can be set 

    Frequency, Amplitude, Bias and Duty of 

        VCO Voltage Control Signal Generator 

    Output function of various parameters such as VCO

Arrows

 

Press Arrow buttons to select figure which you want to 

edit when setting values of each parameter. 

ADJ Knob

 

    Rotate the ADJ Knob to increase or reduce the current value 

indicated by the cursor. 

    Frequency  unit  can  be  changed  by  Press  ADJ  Knob  under 

Frequency value setting status. 

    Press ADJ Knob to Start/Stop sweep under Sweep interface. 

Press the knob as confirmation (OK button). 

Power 

Button 

  The power indicator keeps illuminating when power on. 

  Press the power button  and the indicator change to notifylight status 

and the signal output terminates. 

CH1 channel 

output 

connector 

  CH1 connector, output impedance is 50

Ω

  When  CH1  channel  activates  (indicator  illuminates),  CH1  outputs 

signal with parameters set.   

Output 

Channels

 

Control  CH1  output.  Press  it  to  switch  to  CH1  parameter 

setting interface.   

    Press  it  to  turn  on  CH1  output  with  current 

configuration. The indicator will illuminate.   

      Press it again to turn off CH1 output and the indicator 

will extinguish.

   

Содержание FY8300S Series

Страница 1: ...FeelElec FY8300S Series Fully Numerical Control Three Four Channel Function Arbitrary Waveform Generator User s Manual Rev1 0 May 2019...

Страница 2: ......

Страница 3: ...ly corresponding material FeelElec shall not be liable for losses caused by either incidental or consequential in connection with the furnishing use or performance of this manual as well as any inform...

Страница 4: ...plitude 21 Set Offset 22 Set Duty Cycle Rectangle Set pulse wave pulse width Adj Pulse 23 Set Phase 24 Enable Output 25 Example Output Sine Waveform 26 Burst 28 Modulation Function 28 Frequency Meter...

Страница 5: ...generator Abundant shortcut keys and graphical user interface simplifies every operation Users do not have to spend a lot of time to learn and familiar with the operation of the instrument you can be...

Страница 6: ...guration at the same time when the tracking is opened Can output up to 100 groups of functions arbitrary waveform contains 33 groups of preset waveforms and 64 groups of user defined waveforms Preset...

Страница 7: ...9 the adjusting resolution is 0 01 12V 12V DC Offset function Resolution 0 001V Save function It can save 12 sets user set parameters and can be loaded at any time Communicating function All functions...

Страница 8: ...shipment have been checked for completeness and the instrument has passed both electrical and mechanical tests The consigner or carrier shall be liable for the damage to instrument resulting from shi...

Страница 9: ...are matched with Manu displayed on the LCD Press corresponding button to activate submenu represented 3 Function Buttons Area Press this buttons to switch waveforms among Sine Square Rectangle Triang...

Страница 10: ...or Output function of various parameters such as VCO 4 Arrows Press Arrow buttons to select figure which you want to edit when setting values of each parameter 5 ADJ Knob Rotate the ADJ Knob to increa...

Страница 11: ...to CH3 parameter setting interface Press it to turn on CH3 output with current configuration The indicator will illuminate Press it again to turn off CH3 output and the indicator will extinguish 9 CH...

Страница 12: ...olling offset voltage controlling duty cycle and so on Frequency of external signal input should be lower than 500 Hz SYNC OUT Synchronization signal output terminal SYNC IN Synchronization signal inp...

Страница 13: ...Manual 11 To avoid instrument damage voltage of signal input from EXT IN CANNOT exceed 20Vac dc Voltage of signal input from Trig FSK ASK PSK IN CANNOT exceed DC5V Note To ensure the normal work pleas...

Страница 14: ...s than 10W Power On Turn on the power switch after the power cord is connected The generator will execute self inspection The LCD will show welcome interface after the inspection is over If the genera...

Страница 15: ...ted 1 4 User Interface CH1 selected Item Description 1 Current channel selected Display current channel selected for operation 2 Current waveform selected Display the name of current waveform selected...

Страница 16: ...of the output signals of CH1 CH2 and CH3 channels will be reflected in the waveform display window The waveform amplitude displayed in the window will automatically switch gears according to the actu...

Страница 17: ...anual 15 menu bar will switch in the duty up down function When the drop display value is highlighted the parameter will be changed by the direction key and knob Note The descent edge parameters are o...

Страница 18: ...FeelElec 16 FY8300S Series User s Manual Appearance and Dimensions...

Страница 19: ...nstrument to output various waveforms Select Output Channel CH1 CH2 and CH3buttons are used to change current channel selected At start up CH1 is displayed on the top with yellow color and CH2 is disp...

Страница 20: ...arithm Linear FM AM FM Positive Half Wave Negative Half Wave Positive Half Wave Rectification Negative Half Wave Rectification User defined waveform Press WAVE to change waveform selected Or rotate AD...

Страница 21: ...FY8300 Series User s Manual 19 Note Arbitrary waveforms can be edited and downloaded from PC software provided by FeelElec The relevant software and driver can be downloaded from our website www feel...

Страница 22: ...ncy are different For detailed information please refer to Frequency in Specifications The default frequency is 10kHz Press FREQ button to highlight value of Frequency Then use Arrow buttons and ADJ K...

Страница 23: ...Points 1 What s the difference of amplitude in Vpp and the corresponding value in Vrms Answer Vpp is the unit for signal peak peak value and Vrms is the unit for signal effective value The default un...

Страница 24: ...n and ADJ Knob to set the value Press Arrows button to move the cursor and rotate ADJ Knob to set the value The offset accuracy is 1mV i e 0 001V When frequency output is lower than 20MHz the offset c...

Страница 25: ...setting range of duty cycle is 0 1 99 9 Press ADJ Knob under duty cycle setting status will initial the value to 50 Set pulse wave pulse width Adj Pulse wave Adjustable pulse wave refers to the squar...

Страница 26: ...olution is 0 1 The default phase value is 0 The start phase displayed on the screen is the default value or the phase previously set Then press PHAS button to highlight phase value Then use Arrows but...

Страница 27: ...ent channel selected is not CH1 then press CH1 to make CH1 as channel selected and press CH1 again to switch between output ON OFF For CH2 there are two status 1 Generator is in parameter setting stat...

Страница 28: ...ADJ Knob to get 2 FREQ 00 020 000 000 000kHz 4 Set the Amplitude Press AMPL to highlight the amplitude value Press Arrow buttons to move the cursor and rotate the ADJ Knob to get the figures below AMP...

Страница 29: ...FeelElec FY8300 Series User s Manual 27...

Страница 30: ...orresponding button When the burst function is enabled press the PARA button to set the burst output pulse number Use arrow buttons and ADJ Knob to set the numbers from 1 to 1048575 Then the generator...

Страница 31: ...ernal CH2 External VCO IN Port Modulating Waveform Sine Square Triangle Ramp Arbitrary waveform Modulating Frequency Internal 1 Hz 1MHz External 1 Hz 2KHz PM Source Internal CH2 External VCO IN Port M...

Страница 32: ...FeelElec 30 FY8300S Series User s Manual Key Frequency 1 Hz 10MHz...

Страница 33: ...coupling The result will be displayed on the screen in real time The lowest frequency workable is 0 01 Hz GATE TIME 100S Press COUN button to enter external pulse counter function At this time COUN bu...

Страница 34: ...User s Manual Set the Counter Gate Time Press GATE button to select gate time The default is 1S It s better to use 10S or 100S as gate time for low frequency signal Gate Time Frequency Resolution 1S...

Страница 35: ...rface Sweep Object FY8300S Can output sweep from CH1 The sweep objects include frequency amplitude offset duty cycle It can be selected by pressing OBJE button In Frequency Sweep Mode the generator wi...

Страница 36: ...000 000 000kHz Amplitude Sweep Press STAR button to highlight start amplitude parameter Press the Arrow buttons and rotate the ADJ Knob to set the specified value For example START 10 00V Offset Swee...

Страница 37: ...20 000 000 000kHz Amplitude Sweep Press END button to highlight end amplitude parameter Press the Arrow buttons and rotate the ADJ Knob to set the specified value For example END 20 00V Offset Sweep P...

Страница 38: ...nabled press SOUR button to select it and press it again to change between TIME and external sweep VCO Sweep Press the Arrow buttons and rotate the ADJ Knob to set the specified value of weep time The...

Страница 39: ...n method Press SWEEP button to enter sweep function interface Then press F4 SOUR button to switch the source to VCO IN After Sweep Object Start End and Sweep Mode being set connect the external signal...

Страница 40: ...End value Start value Sweep time 100 Logarithm Sweep In linear sweep type the signal parameter varies logarithmically For example in the frequency sweep the output frequency changes in the way of oct...

Страница 41: ...he generator sweeps from low frequency to high frequency Start Frequency End Frequency the generator sweeps from high frequency to low frequency Start Frequency Stop Frequency the generator outputs wi...

Страница 42: ...waveform parameters of configurable channels 2 and 3 change synchronously with the corresponding parameters of channel 1 CONF To set system language turn on off Buzzer and Uplink mode MORE To set defa...

Страница 43: ...parameters stored in storage location 01 will be loaded automatically at the next boot Select L xx on the right to load parameters from corresponding position to current system status FY8300S provides...

Страница 44: ...utton to turn on off buzzer On is the default Press PHAS button The phase of the three output waveforms can be set in manual automatic state When the waveform parameters are adjusted the phase of the...

Страница 45: ...o set the UPLINK to be ON Set all other machines to be slave machines Press SYS CONF M S to set the UPLINK MODE to be Slave Press UPLI to set the UPLINK to be ON Repeat this step to set all slave mach...

Страница 46: ...ording to variation of CH1 When AMPL is highlighted the amplitude of CH2 CH3 will vary according to variation of CH1 When OFFS is highlighted the offset of CH2 CH3 will vary according to variation of...

Страница 47: ...rument after finishing the above inspections 4 If it still does not work correctly please contact FeelElec CH2 CH3 is locked 1 Check that the signal generator is operating in synchronous state Press t...

Страница 48: ...in Resolution on all frequency range 1 Hz Min resolution can reach 1 Hz on all frequency range to ensure adjusting accuracy under high frequency For example it can output 10 000000000001MHz signal Acc...

Страница 49: ...eform Output Impedance 50 10 Typical Protection All channels can work more than 60 seconds when the load is short circuited DC Offset Offset Range Frequency 20MHz 12V Frequency 20MHz 2 5V Offset Resol...

Страница 50: ...ters setting VCO Voltage Control Output Modulation signal range to input 0 5V VCO signal frequency range 0 1000Hz VCO control object voltage controlling frequency VCF voltage controlling amplitude VCA...

Страница 51: ...cycle Key Frequency 1 Hz 10MHz Burst Function Carrier Waveform Sine Square Ramp Arbitrary except DC Burst Count 1 1048575 Trigger Source Manual Internal External AC DC General Specifications Display T...

Страница 52: ...death and all the company managers and employees and auxiliary agents distributors other personnel concerned will be released from any claim including all the costs expenses attorney fees etc that ma...

Отзывы: