Case Install  

The Inner Outer Duct Assemblies and Retainer Brackets are shipped attached to the case refrigeration 
compartment. The Duct Assemblies and Retainer Brackets must be removed before setting case into 
cabinet opening. To disassemble remove the (8) screws holding each Duct Assembly to the louvered panel 
also remove the (2) screws holding each Retainer Bracket.  
 
The case is shipped without end panels to provide handles to lift case into cabinet.  
Once case is placed into cabinet remove the (4) handles and install side glass as described in End Panel 
Installation section of this manual.  

LIFT HANDLES

 

Once case is in place it must be secured to prevent it from moving during use. Reattach the Retainer 
Brackets that were previously removed in same location using the #8 hex head screws. Push bracket up 
tight to bottom of counter top and tighten screws. Predrill (4) 5/32 holes ½” deep into the counter top. (Be 
careful not to drill through top of counter) 
 

RETAINER

BRACKETS

(2) #10 X 5/8 SCREWS

SCREW INTO BOTTOM OF

COUNTER TOP. PRE DRILL 5/32 HOLES 

1/2" DEEP. BECARFUL NOT TO DRILL 

THROUGH TOP OF COUNTER.

(2) #8 HEX HEAD 

SCREWS ATTACHED 

TO CASE

 

Содержание ITD48

Страница 1: ...ote Refrigerated Models ITD Non Refrigerated Displays KEEP THIS MANUAL FOR FUTURE REFERENCE Engineering and technical data are subject to change without notice FEDERAL INDUSTRIES 215 FEDERAL AVE Belle...

Страница 2: ...Additional Parts 6 Cleaning 6 INSTALLATION INSTRUCTIONS COUNTER MODELS 6 Inspection For Shipping Damage 5 Locating The Display Case 6 Removing Case From Shipping Skid 6 Additional Parts 6 Cleaning 6 C...

Страница 3: ...y Cleaning 23 Weekly Cleaning 24 Weekly Exterior Cleaning 26 SERVICE 27 Service Information 28 Pre Service Checklist 28 Electronic Control Operation 16 SALE DISPOSAL 32 Owner Responsibility 32 WIRING...

Страница 4: ...omponents contain technical instructions intended only for persons qualified to perform electrical work DANGER Improper or faulty hookup of electrical components in the case can result in severe injur...

Страница 5: ...r death will occur if you ignore the message WARNING Severe injury or death can occur if you ignore the message CAUTION Minor injury or damage to your case can occur if you ignore the message NOTICE T...

Страница 6: ...MIN CIRCUIT AMPACITY 15 MAX FUSE SIZE 15 Permanent Connected Only a licensed electrician must perform all case electrical connections All electrical wiring hookups must be done in accordance with all...

Страница 7: ...ments of the case See the electrical data plate located on the rear exterior of the case for the proper circuit size for each case The cord is factory installed protruding from the rear corner of the...

Страница 8: ...834R R134A 1 2HP 3750 BTUH 90F 20F 32 0 ITR6026R ITR6034R R134A 1 2HP 3750 BTUH 90F 20F 32 0 Use pressure gauges to set pressure control Remote Refrigeration Operation The remote models are designed t...

Страница 9: ...trap must be installed in the suction line at the foot of every riser to insure oil return Dry nitrogen must be used to flow through tubing while brazing refrigeration lines 4 Suction line must be ins...

Страница 10: ...that the drain trap terminates properly over the water reservoir Condensate Pump Standard Remote optional Self Contained When unit is shipped with a condensate pump a condensate discharge hose is supp...

Страница 11: ...ECTION BOX ACESS HOLE 2 75O ACESS HOLE 2 75O FILTER DRIER SIGHT GLASS ELECTRICAL CONNECTION 88O 17 3 3 7 9 7 36 30 FRONT TOP VIEW Counter ITR48 Self Contained CONDENSING UNIT CONDENSATE EVAPORATOR OR...

Страница 12: ...DRIER SIGHT GLASS ELECTRICAL CONNECTION 88O 60 30 3 7 3 11 5 17 9 9 FRONT TOP VIEW Floor ITR36 Self Contained CONDENSING UNIT CONDENSATE EVAPORATOR OR PUMP POWER SUPPLY ELECTRICAL CONNECTION BOX ACES...

Страница 13: ...ECTRICAL CONNECTION 88O FRONT TOP VIEW LEG LEVELER PLATES OR CASTER POCKETS 48 30 8 17 5 9 9 9 2 3 5 12 0 Floor ITR60 Self Contained CONDENSING UNIT CONDENSATE EVAPORATOR OR PUMP POWER SUPPLY ELECTRIC...

Страница 14: ...14 Refrigerated Remote Models Counter ITR36 Remote Counter ITR48 Remote...

Страница 15: ...15 Counter ITR48 Remote Floor ITR36 Self Remote...

Страница 16: ...16 Floor ITR48 Remote Floor ITR60 Remote...

Страница 17: ...e or glass breakage will result 1 Remove crate top and sides and note missing or damaged items as explained in the pre installation procedures outlined above 2 Move the case as near as possible to the...

Страница 18: ...skid or moving the case Case damage or glass breakage will result 2 Remove crate top and sides and note missing or damaged items as explained in the pre installation procedures outlined above 8 Move...

Страница 19: ...s provided The case must be sealed to the counter using a NSF Listed Sealant IMPORTANT When placing cases in a line up the number of end panels used will be different The cut out and hole placement di...

Страница 20: ...the number of end panels used will be different The cut out and hole placement dimension will need to be adjusted for each particular line up circumstance See LINE UP INTALLATION section of this manua...

Страница 21: ...placed into cabinet remove the 4 handles and install side glass as described in End Panel Installation section of this manual LIFT HANDLES Once case is in place it must be secured to prevent it from...

Страница 22: ...e and discharge louvered panels can be moved to front of compartment and the solid panels moved to the back of compartment if air intake and discharge is required out of front of cabinet The Outer Duc...

Страница 23: ...ticular line up circumstance See LINE UP INTALLATION section of this manual The condensate air louvers are located on each side of the condensate evaporator compartment Do not block these louvers The...

Страница 24: ...anel clears bottom of base and remove from case Front Panel FRONT PANEL SCREWS FRONT PANEL FRONT PANEL SCREWS TOP PANEL RETAINER 1 Disconnect power to Display Case 2 Remove 2 front panel phillips head...

Страница 25: ...ith one louver panel in front and one in back to allow front condenser air in or out of front and rear air in or out back This must be determined before placing unit into counter and cabinet must be p...

Страница 26: ...ee Case Line Up Installation section of this manual 1 On each side of case there are 3 keyhole mounting slots for easier installation of glass There is 1 mounting hole in the front top corner of case...

Страница 27: ...w the instruction in the illustration below Starting with the longest brackets for bottom shelf insert 1 of the 2 shelf brackets in the desired shelf standard slot on one side of the case Place the lo...

Страница 28: ...ght must be facing towards back of case Hook shelf support end flanges into front notch of shelf brackets on each side of case 6 Install rear shelf supports with no lights on to shelf brackets All she...

Страница 29: ...on Clean area of glass where glass shelf holder is to be located with rubbing alcohol and let air dry before installing shelf glass holder Remove backing from tape located on flat side of glass shelf...

Страница 30: ...h the outer door and lift the door upward until the bottom edge of door clears the lower track and then swing the bottom of the door outward and down out of upper track 2 After the outer door is remov...

Страница 31: ...H POWER SWITCH Power Switch The unit has a power switch that turns off power to the entire unit including the condensate evaporator and the lights Light Switch The unit has a light switch that turns o...

Страница 32: ...on press and hold for approx five seconds The display will read On while the button is depressed When the control powers on the display will read the relative current case temperature on initial star...

Страница 33: ...is being held The defrost is initiated when the defrost mode indicator illuminates on the display The control display will then return to reading the case temperature When the defrost mode indicator...

Страница 34: ...distributed evenly across the entire shelving area Determine desired shelving location and angle before placing product in case Product must be removed to readjust shelf location and angle Refrigerate...

Страница 35: ...OIL BACK PANELS COUNTER ITR MODEL It is very important that the Condenser coil is cleaned twice per month to insure proper refrigeration performance and to prevent compressor failure Failure to clean...

Страница 36: ...unit does not have a time clock so the defrost cycles cannot be set for any specific time of day The unit also has an On demand defrost feature that will initiate a defrost when the temperature differ...

Страница 37: ...ely read overload or very high in the mega ohm range 3 Ensure that probes are wired per the wiring diagram provided 4 Replace probe if other remedies fail or if probe resistance deviates from Error Re...

Страница 38: ...r switch and light switch to off position 3 Remove Shelf from display case 4 Unplug 24v DC power wire from end of existing LED light strip 5 Remove the shelf support with light from case 6 Use a putty...

Страница 39: ...ior tilt the front glass forward Tilt the front glass out by grabbing the top edge of glass with finger tips and pulling it away from magnetic strips on case Tilt glass until it stops at about 30 degr...

Страница 40: ...rical components with water to prevent electrical damage to the case NOTICE Shut off lights and power switches and remove all product from case Allow sufficient time for the unit to reach room tempera...

Страница 41: ...o dry 9 Clean behind front glass hing using warm soapy water and sweeping debris to each end and 10 Clean all foreign material from inner and outer rear door tracks using warm soapy water and a brush...

Страница 42: ...e refrigerant charge be evacuated into a recovery system to prevent the possibility of hydrofluorocarbons HFC s from being released into the atmosphere If moisture or liquid is observed around or unde...

Страница 43: ...ght strip upside down Case Temperature Too Warm Check that the cold air inlet and outlet slots are not blocked Be sure that the rear doors are closed and tightly sealed Check for a blocked or dirty co...

Страница 44: ...customer service department at Federal Industries at 800 356 4206 The customer service department at Federal Industries should be contacted at the time of sale or disposal of your case so records may...

Страница 45: ...L 120V 1PH 60HZ DARK LINES REPRESENT CONDUCTOR CORD ITR SELF CONTAINED MODELS 91 20568 4 25 16 Y W W 4 5 9 6 7 10 8 R TEMP PROBE DEFROST PROBE SHELF LIGHT W 24V POWER SUPPLY 2 FANS 5 ONLY RIB LIGHT QU...

Страница 46: ...H RIB RIB RIB TOP LIGHT CONDENSATE PUMP OR EVAPORATOR G Y B BRW RIB RIB RIB RIB B R B R BLK RIB BLK RIB BLK BLK M PLUG BLK RIB BLK SHELF LIGHT SHELF LIGHT BLK BLK BLK W BLK G Y BLK RIB BLK C BLK W R B...

Страница 47: ...20472 2 50 20471 L 50 20471 R 50 20471 1LA 50 20471 1RA 64 20476 2 64 20476 4 ITR6034 50 20471 3 50 20472 3 50 20471 L 50 20471 R 50 20471 1LA 50 20471 1RA 64 20476 3 64 20476 4 REFRIGERATION COMPONE...

Отзывы: