Installation and Maintenance Instructions

5

Models VSLR1 and VSLR1-IPX

Figure 3  Wiring for Models VSLR1 and VSLR1-IPX

290A6950

RED

BLACK

RED

INSULATED BUTT

CONNECTORS

(INSTALLER SUPPLIED)

8 A

FUSE

(+) TO POWER

SOURCE

(−) TO GROUND

BLACK

RED

SWITCH

Cleaning the Plastic Dome 

CRAZING/CLEANING SOLUTIONS—The use of other materials such as strong 

detergents, solvents, petroleum products, etc. can cause crazing (cracking) of the 

plastic domes. If crazing of domes does occur, reliability of light for emergency 

purposes may be reduced until domes are replaced. Failure to follow this warning 

can damage the domes, reducing the effectiveness of the lighting system, and may 

result in injury or death.

CRAZING/CHEMICALS—Crazed, cracked or faded domes reduce the light output and 

the effectiveness of the lighting system. Domes or reflectors showing this type of 

aging must be replaced. Failure to follow this warning may result in injury or death.

To clean the dome:

1.

  Rinse the dome with lukewarm water to loosen dirt and debris.

2.

  Use a mild detergent, lukewarm water, and a soft cloth to gently clean the dome. To avoid damaging the 

finish, do not use heavy pressure or caustic, abrasive, or petroleum-based cleaners.

3.

  Rinse and dry the dome with a soft cloth to prevent water spotting.

4.

  To remove fine scratches and haze, use a soft cloth and a high quality automotive paste cleaner/wax that 

is non-abrasive or a plastic polish like Plexus

®

Содержание VSLR1 Series

Страница 1: ...y or chassis part that will provide an effective ground path as long as the light system is to be used Refer to the instructions packed with related products for additional precautions and information...

Страница 2: ...cm x 25 4 cm 5 0 in x 7 3 in x 10 0 in 12 7 cm x 18 5 cm x 25 4 cm Amperage 1 8 12 Vdc 1 0 24 Vdc 2 8 12 Vdc Unpacking the Product After unpacking the product inspect it for damage that may have occu...

Страница 3: ...position marks on the mounting surface DRILLING PRECAUTIONS When drilling holes check the area into which you are drilling to be sure you do not damage vehicle components All drilled holes should be...

Страница 4: ...ed in the leads The basic light functions of the unit must be controlled by a installer supplied control head Before proceeding ensure that the light assembly has been installed on the vehicle roof in...

Страница 5: ...e effectiveness of the lighting system and may result in injury or death CRAZING CHEMICALS Crazed cracked or faded domes reduce the light output and the effectiveness of the lighting system Domes or r...

Страница 6: ...2 See Figure 4 Use a T25 Torx driver to remove the 10 32 Torx shoulder screw 3 Carefully lift the dome from the back and rotate it to a vertical position to avoid damaging the pod hook and pod base g...

Страница 7: ...32 screw securing it to the pod base 2 Insert the 10 32 Torx shoulder screw into the hole through the tip of the dome and into the pod base To prevent cross threading back the screw counterclockwise...

Страница 8: ...a pod 1 Reconnect the electrical connector to the pod 2 Place the pod atop in the correct location in the light assembly and rotate it clockwise 3 Insert the 10 32 x 1 4 Torx shoulder screw into the h...

Страница 9: ...ttle or damaged Replace it if necessary Installing an Impaxx To reinstall an Impaxx 1 Install the gasket on the Impaxx The wider end of the gasket goes down touches the base plate 2 Install the bracke...

Страница 10: ...Parts This section contains a partial list of replacement parts To order replacement parts call the Federal Signal Service Department at 800 433 9132 7 a m to 5 p m Monday through Friday Central Time...

Страница 11: ...Federal Signal customer or account number The purchase order number under which the items were purchased The shipping method The model or part number of the product being returned The quantity of prod...

Страница 12: ...and VSLR1 IPX 2012 Federal Signal Corporation 2645 Federal Signal Drive University Park IL 60484 3167 Tel 800 264 3578 Fax 800 682 8022 www fedsig com 3 00 in 0 375 in 0 281 in 290A6953 1 5 in 1 0 in...

Отзывы: