Safety Messages to Installers and Users 

Products should be installed to code by a licensed electrician 

and follow all safety instructions. Failure to do so may result in property damage, serious injury, or death.
•  Read and understand instructions before installing or operating equipment.
•  To avoid electrical shock hazards, do not connect wires when power is applied.
•  To be an effective warning device, this product produces bright light that could be hazardous to eyesight. 

The possibility exists that rapid flashing lights could induce photosensitive epilepsy. Do not stare directly at 

the light.

Overview: 

Models 121ALED and 121ALED-N rotating LED warning lights are designed for mounting on a flat 

(horizontal or vertical) surface or on a 1/2” NPT threaded pipe. Units are available in 24VDC. 

Certifications and Ratings:

•  UL and cUL Listed
•  Type 4X, IP66 enclosure. Indoor/Outdoor Use
•  IP69K Compliant
•  Model 121ALED-N is NSF Certified 

(dome-up)

 for  

Splash Zones and Non-food Zones to  

NSF/ANSI 2: Food Equipment

•  Electrical ratings: 

024VDC, 0.3A

•  Certified operating temperature:  

-40°F to 150°F (-40°C to 66°C)

Installation:

Unpacking the Device: 

After unpacking the device, examine it 

for damage and verify parts. Unit comes with: (1) 121ALED or 

121ALED-N assembled unit with flying leads, (1) panel mount 

gasket, and (3) # 8-32 panel mounting tapping screws. If a part is 

missing or damaged do not install. Contact Federal Signal Customer 

Support at +1 708-534-4756 or [email protected].

Electrical Connections 

To avoid electrical shock, do not 

connect wires when circuits are energized. Use 18AWG field wiring 

or larger.

•  24VDC Models: 

Connect the positive (+) power source lead to 

the red wire and connect the negative (-) power source lead to 

the black wire.

Mounting the device: 

Units come standard to mount on a flat 

(horizontal or vertical) surface or a 1/2" NPT pipe. Model 121ALED-N 

(NSF Certified) must be mounted in a dome up position to resist 

water and debris accumulation and maintain the NSF Certification. 

Wall or corner mounting accessories are sold separately. 

•  Pipe Mounting  –  

On a 1/2" NPT Pipe, feed wires through pipe 

and turn clockwise to tighten. Recommended tightening torque is 5-ft-lbs (6.8 N-m).

•  Surface/Panel Mounting  –  

Using provided gasket as template, mark three mounting holes and center 

hole for wiring. Drill or punch 3/16" (4.8mm) diameter holes for mounting and a 1" (25.4mm) for wiring. Set 

base on gasket, feed wires through center, and attach to the mounting surface using provided #8 tapping 

screws from the underside.

Installation and Maintenance Instructions

121ALED and 

121ALED-N 

Beacon

Junction box 

(not supplied)

1/2" conduit 

(not supplied)

Wiring

Wiring 

(red wire to 

positive (+)
Power source 

and black wire

To negative (-) 

power source).

1/2" NPT 

Pipe Mount

5.12"/ 130 mm

6.26"/ 159 mm

LED Lamp

Parabolic 

Reflector

Elliptical Dome

(12" Curvature

 Radius) 

Screw

in Base

Содержание Vitalite 121ALED

Страница 1: ...led unit with flying leads 1 panel mount gasket and 3 8 32 panel mounting tapping screws If a part is missing or damaged do not install Contact Federal Signal Customer Support at 1 708 534 4756 or iordersup fedsig com Electrical Connections To avoid electrical shock do not connect wires when circuits are energized Use 18AWG field wiring or larger 24VDC Models Connect the positive power source lead...

Страница 2: ...ward socket while turning counterclockwise 6 Insert the new lamp while gently pushing it toward the socket and turning clockwise 7 Before replacing dome ensure the gasket is properly seated on the housing base 8 Place dome over base and aligning recesses inside dome lip with four pins on the base Push down on the dome and turn clockwise until it locks in place approximately 9 Replace set screw on ...

Страница 3: ...alación Desembalaje del dispositivo después de desembalar el dispositivo examínelo para detectar daños y verifique las piezas recibidas La unidad se comercializa con los siguientes componentes 1 unidad ensamblada 121ALED o 121ALED N con cables de conexión 1 junta para montaje en panel y 3 tornillos autorroscantes n º 8 32 para montaje en panel Si detecta que falta una pieza o está dañada no instal...

Страница 4: ...tá disponible para su compra deberá reparar o reemplazar su unidad Cambio de la lámpara LED 1 PELIGRO DE DESCARGA ELÉCTRICA Desconecte la corriente eléctrica Deje que la lámpara se enfríe 2 Retire el tornillo de fijación ubicado en la parte inferior de la cúpula 3 Sujete la parte superior de la cúpula y empújela hacia abajo mientras la gira en sentido antihorario 4 Retire la cúpula y asegúrese de ...

Страница 5: ...à 150 F Installation Déballage de l appareil après avoir déballé l appareil examinez le pour voir s il est endommagé et vérifiez les pièces L emballage contient les éléments suivants 1 unité 121ALED ou 121ALED N assemblée avec fils volants 1 joint pour montage sur panneau et 3 vis autotaraudeuses n 8 32 pour montage sur panneau N installez pas l appareil si une pièce est manquante ou endommagée Co...

Страница 6: ...ible à l achat votre unité doit être réparée ou remplacée Remplacement de la lampe LED 1 RISQUES DE CHOCS ÉLECTRIQUES coupez le courant Laissez la lampe refroidir 2 Retirez la vis de serrage située au bas du dôme 3 Saisissez le haut du dôme et poussez le vers le bas tout en le tournant dans le sens inverse des aiguilles d une montre 4 Retirez le dôme et assurez vous que le joint entre le dôme et l...

Отзывы: